Setting The Status Window Mode; Setting The Fault Window Attributes; Turning On The Fault Window Backgrounds; Setting The Fault Window Background Colours - evertz 7735CEM Manual

Composite encoder with monitoring
Table of Contents

Advertisement

7.8.4.8. Setting the Status Window Mode

On-screen display configuration
Text windows
Text window config
Status window mode
Normal
Fault

7.8.5. Setting the Fault Window Attributes

The On screen Fault windows can be displayed as white characters with or without a coloured
background. In addition the text and background opacity or how much video picture content will be visible
through the text or background is adjustable. The Fault window config menu items are used to set these
parameters for the Fault windows.

7.8.5.1. Turning on the Fault Window Backgrounds

On-screen display configuration
Text windows
Fault window config
Text type
White on bkgrn
White with no
bkgrnd

7.8.5.2. Setting the Fault Window Background Colours

On-screen display configuration
Text windows
Fault window config
Background colour
Black
Grey
Yellow
Red
Green
Gray background indicate un-implemented or un-tested features
7735CEM Composite Encoder with Monitoring
This control determines the display properties of the status
window.
When it is set to Normal the status window will use the text window
properties.
When it is set to Fault, items in the status window that have been
selected for fault generation using the Fault Trigger menu item will
use the Fault window properties when the fault is active. If the
status window is enabled by either Fault 1 or Fault 2 triggering,
then only the faults that actually enabled the window will be shown
in the Fault window properties. The rest of the items on the status
window will be shown in the Text window properties.
For example, if "program rating" is set up as a fault trigger, and the
rating disappears, then the "program rating" line of text on the
status screen will take up the characteristics of the "fault text".
Usually this is white text on a red background.
The text displayed in the fault window may either have a
background box or if too much video information is hidden, it
may be inserted with a thin black outline.
Select the desired background colour around the text in the fault
windows.
Revision 1.1.1