7.8.2.1. Setting the Horizontal Position of On Screen Windows

On-screen display
configuration
Window position
Status window H
0 to 39
7

7.8.2.2. Setting the Vertical Position of On Screen Windows

On-screen display
configuration
Window position
Status window V
0 to 19
7

7.8.3. Selecting What Bar Graphs And Windows To Display

The CEM has two general purpose inputs that can be programmed to turn the Level or Phase bar graphs
or the Status, VITC, Program Rating, SID, CC/XDS, or XDS windows on or off, and to clear the level bar
graphs PEAK HOLD or the Fault Displays. The windows and bar graphs can also be turned permanently
on or off. The Window enable menu item is used to program the GPIs, and the on/off states of the text and
bar graph windows. To display the Fault windows use the Fault condition menu item on the Fault
definitions menu. (See section 7.10.1.4)
When you select the Window enable menu item you are presented with a list of the possible functions that
can be controlled using the GPIs as shown in Table 7-3. Select the desired function using the toggle
switch. When the pushbutton is pressed, the cell cycles through the valid values for the field. Each of the
windows and bar graph displays can be set to On, Off or GPI. When set to On, the corresponding window
or bar graph is always displayed. When set to Off, the window or bar graph is always off. When set to GPI,
the window will be on when the configured GPI is active. The GPI columns will either be blank or will
contain the GPI1 or GPI2. When they are set to GPI1 or GPI2 the window will be turned on when the
respective GPI goes active.
Note that the Peak holds and the Clear faults items cannot be set to On or Off. They must be cleared with
the GPI's or the main menu Clear faults and peaks menu item (see section 7.12).
7735CEM-38
Gray background indicate un-implemented or un-tested features
The Window H position menu item sets the leftmost character position for
the respective window.
When you select this parameter, the screen text will disappear and a box of
the correct size will appear. Move it around to the desired position with the
toggle switch. Press the pushbutton when done.
The Window V position menu item sets the top row for the respective
window.
When you select this parameter, the screen text will disappear and a box
of the correct size will appear. Move it around to the desired position with
the toggle switch. Press the pushbutton when done.