Setting The Phase Bar Graph Type; Setting The Bar Graph Error Region; Setting The Bar Graph Warning Region; Setting The Level Bar Graph Scale Position - evertz 7735CEM Manual

Composite encoder with monitoring
Table of Contents

Advertisement

7700 MultiFrame Manual
7735CEM Composite Encoder with Monitoring

7.7.6. Setting The Phase Bar Graph Type

Bar graphs
Bar graphs 1 and 2
Phase type
Stereo
DIN

7.7.7. Setting the Bar Graph Error Region

Bar graphs
Bar graphs 1 and 2
Error region
-1 to –20 dB FS
-6 dB FS

7.7.8. Setting the Bar Graph Warning Region

Bar graphs
Bar graphs 1 and 2
Warning region
-2 to –40 dB FS
-20 dB FS

7.7.9. Setting the Level Bar Graph Scale Position

Bar graphs
Bar graphs 1 and 2
Scale position
Off
Left
Right
7735CEM-32
Gray background indicate un-implemented or un-tested features
There are two types of phase bar graphs available: one that has a focus
of presenting the amount and L/R distribution of stereo content
(STEREO), and one that presents in-phase/out-of-phase proportions
(DIN).
The bar graph "error" region is the area from clipping (0 dB FS) down to
the level selected by this control. It is intended to tell the user when the
audio signal is getting close to clipping.
Warning:
Some bar graph types (and ballistics) have this region defined. When you
select one of these types, this value will automatically be set. After you
choose the type, you can adjust this value to your desired level.
The bar graph "warning" region is the area between the "OK" region and
the "error" region. It is intended to indicate when the audio level is
approaching the "error" region. This control sets the bottom of the
"warning" region. Normally, it is set to the audio program level. The
upper boundary of this region is always set with the "error" region
control.
This value cannot be higher than the "error" region value. If the "error"
region is lowered below the value of this parameter, the "warning" region
will also be lowered.
Warning:
Some bar graph types (and ballistics) have this region defined. When
you select one of these types, this value will automatically be set. After
you choose the type, you can adjust this value to your desired level.
This control allows you to enable and position the level bar graph scale
tick marks and the scale labels with respect to the bar itself. When off,
there will not be any ticks or numerical labels while left or right will
position them to the left or the right of the graphs respectively.
If a combination VU/PPM mode is selected, then "left" will select VU
scale on the left, PPM scale on the right and "right" will select VU scale
on the right and PPM scale on the left.
Revision 1.1.1