The power of the suction strips will drop off if the seal between
the top and bottom sections is defective. For this reason, the filter
material may not be clamped in between the sealing ring and top
part at any point.
6. Put on the top part while ensuring that the filter material is not clamped in
between the sealing ring and top part at any point when doing so.
7. Screw down the top part.
8. Screw on the ink separator.
9. Connect the hoses.
8 Checking and replacing air filter
Energized components!
Risk of death via electric shock
Switch off printer with the main switch.
Secure the main switch with a lock.
Hot surfaces!
Risk of burns
Wait at least 1 hour after switching off until the UV lamps have cooled
down before attempting replacement.
Wear protective gloves.
Encoder ruler could be scratched!
Reduced functionality of the printer
Do not touch the encoder ruler with hard objects.
1. Switch off printer with the main switch.
2. Secure the main switch with a lock.
3. Manually push the print carriage to a suitable position.
4. Disconnect printer from the power supply.
5. Fold the corresponding front panel up.
G Service