BOARD CON NE CTO R S
T
he following table lists the various sockets, pin headers and
switches located on the panel and their functions.
Connector
This socket allow you to connect a service
Service
Keypad to the panel during installation.
This socket is used to connect the panel
Tamper
enclosure tamper switch.
This push button is used to reset the control
Default
panel back to factory default.
Voice
This is used to connect the optional Voice
Module
Command Module (CM100).
This socket is used to connect serial devices to
Serial
the control system like a Serial STU.
This is a RJ12 6P/4C connector that allows
Telco
you to connect the control panel to the PSTN
telephone line.
The relay select PIN's allow you to easily
Relay
program the relay common contact to switch
either +12v or GND by fitting a plug on link.
Table 10: Board Connector Descriptions
TERMINA L D ESCR IPT ION S
Name
Earth wire from this terminal is connected to
1
Earth
the Mains earth.
2
~ (AC)
Connection of the A.C. plug pack transformer
3
~ (AC)
4
BAT (-)
Negative and positive connections to the
5
BAT (+)
stand-by battery. 12 VDC / 7AH
6
+12 V
7
+12 V
8
+12 V
These terminals are used to power detectors
9
GND
and LAN devices up to 750 mA.
10
GND
11
GND
12
LAN +
These terminals are used to power LAN
13
LAN -
devices up to 750 mA.
Connect the LAN A data terminal of any LAN
device (eg. Keypads, expansion boards) to
14
LAN A
this terminal. The control panel supports up
to 300 m of 24/0.20 (18 AWG) wire on these
terminals.
Connect the LAN B data terminal of any LAN
device (eg. Keypads, expansion boards) to
15
LAN B
this terminal. The control panel supports up
to 300 m of 24/0.20 (18 AWG) wire on these
terminals.
Alarm power capable of providing a
16
COMM+
maximum of 2 Amp (+). This terminal is PTC
Fuse protected.
17
OUT 1
Programmable output, capable of providing
18
OUT 2
a maximum of 500 mA (-). This terminal is
19
OUT 3
PTC Fuse protected.
20
N/C
21
COM
2 A @ 24 VDC Relay Output - Form C contact
22
N/O
3-2
Wiring Diagrams
Description
Description
Name
Programmable Input for RF Receivers,
23
INPUT
Keyswitch and other devices.
24
ZN 1
Zone 1 and 9 sensor loop input (+).
25
GND
Common (-) for Zone 1 and 2 sensor loop.
26
ZN 2
Zone 2 and 10 sensor loop input (+).
27
ZN 3
Zone 3 and 11 sensor loop input (+).
28
GND
Common (-) for Zone 3 and 4 sensor loop.
29
ZN 4
Zone 4 and 12 sensor loop input (+).
30
ZN 5
Zone 5 and 13 sensor loop input (+).
31
GND
Common (-) for Zone 5 and 6 sensor loop.
32
ZN 6
Zone 6 and 14 sensor loop input (+).
33
ZN 7
Zone 7 and 15 sensor loop input (+).
34
GND
Common (-) for Zone 7 and 8 sensor loop.
35
ZN 8
Zone 8 and 16 sensor loop input (+).
36
IN
These terminals are used to connect the
37
IN
telephone line from the street.
38
OUT
These terminals are used to connect the
39
OUT
premises telephones.
Table 11: Terminall Block Descriptions and Functions