Global View Station 1000
6.2
Auxiliary Control Board
Figure 6.11 Auxiliary Control Board
Component Description
SW1
Board reset button
JP6
T1 telemetry jumper
JP7
T2 telemetry jumper
T1
RS485/422 telemetry input to board
T2
N/A
T3
Aux8 SLED power input to SLED current control boards
T4
24 VDC supply indicator
T5
Aux 7 ZX700 power output from main PSU
T6
Aux 8 SLED #1 power output from current control board #1
T7
Aux 8 SLED #2 power output from current control board #2
LED1
Aux 1 Doubler status indicator
LED2
Aux 2 Wiper status indicator
LED3
Aux 3 photocell control indicator
LED5
Aux 5 IR mode indicator
LED6
Aux 6 camera NIGHT mode indicator
LED7
Aux 7 ZX700 telemetry on indicator (indicates telemetry status set to ON)
LED8
Aux 8 SLED telemetry on indicator (indicates telemetry status set to ON)
LED9
Auxiliary board power input indicator
LED10
RS485/422 data input indicator (constantly on in SELF-TEST mode). Flashing when receiving data
LED11
Power input to SLED current control boards
LED12
24 VDC system power indicator
LED13
Aux 7 ZX700 power on indicator (indicates actual power output to both ZX700 units)
LED14
Aux 8 SLED #1 power on indicator (indicates actual power output to SLED unit)
LED15
Aux 8 SLED #2 power on indicator (indicates actual power output to SLED unit)
CN1
NC
CN2
NC
CN3
Aux 7 relay connection to Main PSU
CN4
Aux 8 relay connection to current control boards #1 & #2
CN5
12 VDC input connection to VRB
CN6
NC
CN7
Photocell connection
DIP1
Switches 1-4 for system address setting; switch 5 for Pelco P/D selection; switch 6 for diagnostics
function on/off control
VR1
Photocell sensitivity adjustment
Bosch Security Systems, Inc.
Operations Manual
Test Software | en
29
F.01U.173.867 | 2.0 | 2010.11