Wiring Diagrams; Board Connectors; Terminal Descriptions; Table 12: Board Connector Descriptions - Bosch Solution 16i Installation Manual

Hide thumbs Also See for Solution 16i:
Table of Contents

Advertisement

Solution 16i
Installation Manual
B O A R D CO N N E C TO R S
T
he following table lists the various sockets, pin headers
and switches located on the panel and their functions.
Connector
This socket allow you to connect a service
Service
Keypad to the panel during installation.
This socket is used to connect the cabinet
Tamper
tamper switch to the panel.
This push button is used to reset the con-
Default
trol panel back to factory default and to
enable Direct Link Programming Mode.
Voice
This is used to connect the optional Voice
Module
Command Module (CM101B).
This socket is used to connect the Direct
Direct Link
Link Interface (P/N CM900B) or the Flash
Port
Programmer Interface (P/N CM901) to the
panel.
This is a RJ12 6P/4C connector that allows
Telco
you to connect the control panel to the
PSTN telephone line.
Expansion
Used to connect addition modules to the
Port
control panel. eg TCP/IP interface.
LAN Term
Used to terminate the RS485 LAN.

Table 12: Board Connector Descriptions

T E R M I N A L D E S C R I P T I O N S
Name
Earth wire from this terminal is
1
Earth
connected to the Mains earth.
2
~ (AC)
Connection of the 16-18V AC 50-60 Hz
3
~ (AC)
adapter or internal transformer.
4
BAT (-)
Negative and positive connections to
5
BAT (+)
the stand-by battery. 12 VDC / 7.2AH
6
+12 V
These terminals are used to power
7
+12 V
detectors and other accessory devices.
8
GND
(750mA Fused)
9
GND
10
LAN +
These terminals are used to power LAN
11
LAN -
modules and devices. (750 mA Fused)
Connect the LAN A data terminal of any
LAN device (eg. Keypads, expansion
12
LAN A
boards) to this terminal. The control
panel supports up to 300 m of 24/0.20
(18 AWG) wire on these terminals.
Connect the LAN B data terminal of any
LAN device (eg. Keypads, expansion
13
LAN B
boards) to this terminal. The control
panel supports up to 300 m of 24/0.20
(18 AWG) wire on these terminals.
Common positive terminal for system
14 COMM+
outputs. This terminal is 2.5A PTC Fuse
protected.
3-2

Wiring Diagrams

Description
Description
Name
15
OUT 1
Fully supervised programmable, open
16
OUT 2
collector outputs capable of driving
17
OUT 3
(sink) loads up to 1 amp for sirens,
18
OUT 4
strobes etc.
Programmable Input for RF Receivers,
19
INPUT
Keyswitch and other devices.
20
ZN 1
Zone 1 and 9 sensor loop input (+).
21
GND
Common (-) for Zone 1 & 2 sensor loop.
22
ZN 2
Zone 2 and 10 sensor loop input (+).
23
ZN 3
Zone 3 and 11 sensor loop input (+).
24
GND
Common (-) for Zone 3 & 4 sensor loop.
25
ZN 4
Zone 4 and 12 sensor loop input (+).
26
ZN 5
Zone 5 and 13 sensor loop input (+).
27
GND
Common (-) for Zone 5 & 6 sensor loop.
28
ZN 6
Zone 6 and 14 sensor loop input (+).
29
ZN 7
Zone 7 and 15 sensor loop input (+).
30
GND
Common (-) for Zone 7 & 8 sensor loop.
31
ZN 8
Zone 8 and 16 sensor loop input (+).
32
IN
These terminals are used to connect the
33
IN
telephone line from the street.
34
OUT
These terminals are used to connect the
35
OUT
premises telephones.

Table 13: Terminal Block Descriptions and Functions