Te rmi nal De sc ri pti on s
Name
Earth wire from this terminal is connected
1
Earth
to the Mains earth.
2
~ (AC)
Connection of the A.C. plug pack
3
~ (AC)
transformer
4
BAT (-)
Negative and positive connections to the
5
BAT (+)
stand-by battery. 12 VDC / 7AH
6
+12 V
7
+12 V
These terminals are used to power
8
+12 V
detectors and LAN devices up to 750
9
GND
mA.
10
GND
11
GND
12
LAN +
These terminals are used to power LAN
13
LAN -
devices up to 750 mA.
Connect the LAN A data terminal of any
LAN device (eg. Keypads, expansion
14
LAN A
boards) to this terminal. The control
panel supports up to 300 m of 24/0.20
(18 AWG) wire on these terminals.
Connect the LAN B data terminal of any
LAN device (eg. Keypads, expansion
15
LAN B
boards) to this terminal. The control
panel supports up to 300 m of 24/0.20
(18 AWG) wire on these terminals.
Alarm power capable of providing a
16 COMM+
maximum of 2 Amp (+). This terminal is
PTC Fuse protected.
17
OUT 1
Programmable
18
OUT 2
providing a maximum of 500 mA (-). This
19
OUT 3
terminal is PTC Fuse protected.
20
N/C
2 A @ 24 VDC Relay Output -
21
COM
Form C contact
22
N/O
Programmable Input for RF Receivers,
23
INPUT
Keyswitch and other devices.
24
ZN 1
Zone 1 and 9 sensor loop input (+).
Common (-) for Zone 1 and 2 sensor
25
GND
loop.
26
ZN 2
Zone 2 and 10 sensor loop input (+).
27
ZN 3
Zone 3 and 11 sensor loop input (+).
Common (-) for Zone 3 and 4 sensor
28
GND
loop.
29
ZN 4
Zone 4 and 12 sensor loop input (+).
30
ZN 5
Zone 5 and 13 sensor loop input (+).
Common (-) for Zone 5 and 6 sensor
31
GND
loop.
Bosch Security Systems 09/06 BLCC100R
Description
output,
capable
Name
32
ZN 6
Zone 6 and 14 sensor loop input (+).
33
ZN 7
Zone 7 and 15 sensor loop input (+).
Common (-) for Zone 7 and 8 sensor
34
GND
loop.
35
ZN 8
Zone 8 and 16 sensor loop input (+).
36
IN
These terminals are used to connect the
37
IN
telephone line from the street.
38
OUT
These terminals are used to connect the
39
OUT
premises telephones.

Table 4: Terminal Block Descriptions

B oa rd Co nnec tor s
Connector
This socket allow you to connect a service
Service
Keypad to the panel during installation.
This socket is used to connect the panel
Tamper
enclosure tamper switch.
This push button is used to reset the con-
Default
trol panel back to factory default.
Voice
This is used to connect the optional Voice
Module
Command Module (CM100).
This socket is used to connect serial devic-
Serial
es to the control system like the direct link
programming module.
This is a RJ12 6P/4C connector that allows
Telco
you to connect the control panel to the
PSTN telephone line.
of
The relay select PIN's allow you to eas-
ily program the relay common contact to
Relay
switch either +12v or GND by fitting a plug
on link.

Table 5: Board Connector Descriptions

Abou t The Key pa d
The Graphic Keypad has 20 keys or buttons. The buttons
allow you to input instructions and navigate the menu
screens as required. Some buttons have a secondary
function which is activated by holding them down for two
seconds. Each button's function is described below
Key pa d Key Fu nc tions
Key
to
Solution 16
Quick Start Guide
plus
Description
Description
Description
The numeric keys allow you to enter
you numbers when required
Use the [MENU] and the numeric keys
to enter commands. The [MENU] key
is also used to go back one level when
navigating through menus or to exit a
programming location without saving
changes.
9