set if the panel is in the disarmed state and all power is removed for
service work to be done. When the power is reapplied, the panel
will start in the disarmed state. Any zone that was programmed as
bypassed when the power was removed will remain bypassed when
the power supply has restored.
If this option is not programmed, the system will always power up in
the armed All On state and any zones bypassed prior to power loss
will power up as un-bypassed zones.
Fault Acknowledge All Areas
Setting this option allow system trouble faults to be acknowledged
from any area or keypad on the system without the need to toggle
over to the area the fault occurred in.
Delay Trouble Beeps
Setting this option will prevent any system trouble events from
sounding the keypad speaker between the hours of 10pm until 7am.
During this time, any new trouble events will be shown in the keypad
display.
If any trouble events are still in effect at 7am, the keypad will begin
sounding the trouble alert to notify the user of the problem. The func-
tion is primarily for use in residential installations.
System > Options >
Keypad Idle Screen
0 = No Idle Screen
1 = Date and Time
(*** System Wide Parameter ***)
This menu allows you to sellect a keypad Idle Screen which will
appear on the display when there has been no activity at the
keypad for a period of 2 minutes. The keypad display will return
to normal as soon as any key has been pressed.
The are two built-in Idle Screens and one custom Idle screen
which can be created and programmed only via the SolutionLink
upload/download software. The custom screen can be used
to display the Installer name and logo or other information as
required.
All keypads on the system will display the same screen saver.
See the examples below.
1)
Press [MENU] + [7] + [7] + [2]. The keypad will display the
current Keypad Idle Screen option.
Keypad Idle Screen
00 - No Idle Screen
Press  0-9 OK to SAVE
2)
Use the up and down arrow keys to select which idle screen
you want to display then press [OK] to save and exit or press
[MENU] to exit without saving.
Wed 05-Jan-2005
Time > 10:34am
Bosch Security Systems 05/10 BLCC100I
MENU 7-7-2
2 = Time
3 = Custom Screen
Solution 16
plus
System > Options >
Keypad Hi/Lo Temp
(*** System Wide Parameter ***)
This menu allows you to set the keypad High and Low
temperature values which the system will monitor. Valid
temperatures are from 00 ˚C minimum to a maximum of 50 ˚C
with a tolerance = +/- 1 ˚C.
If the temperature on the selected keypad falls below the
minimum set temperature then the keypad will display 'Low
Temp xx˚C If the temperature increases above the maximum
set temperature then the keypad will display High temp xx˚C.
Where xx = the set temperature to be monitored.
(*** System Wide Parameter ***)
Press [MENU] + [7] + [7] + [3]. The keypad will display the
1)
current temperature settings.
0
Keypad Hi/Lo Temp
High Temp
00
Press  OK to SAVE
2)
Use the up and down arrow keys to program the High and Low
temperatures. Use the left and right arrow keys to move
between the High and Low temperatures.
Valid range =( 0˚C to 50˚C).
Press [OK] to save and exit or press [MENU] to exit without
3)
saving.
System > Installer Options >
Installer Options
1
Report/Log Entry/Exit Intstaller Menu
2
Report/Log Program Data Change
3
Arm Only Installer PIN
4
Reserved
5
Auto Exit Installer Menu In 2 Hours
6
Auto Exit Service mode In 2 Hours
7
Reserved
8
Factory Defaulting Allowed
This menu allows you to configure the Installer system options.
(*** System Wide Parameter ***)
1)
Press [MENU] + [7] + [7] + [4]. The keypad will display the
current Installer options.
Report Installer
 Report Prog Change
Arm Only Installer PIN
Press  OK ON OFF MENU
Installation Manual
System Programming
10:34am
-
0
0
˚C
Hi TEMP
Low Temp
00
MENU 7-7-3
0
0
˚C
Lo TEMP
MENU 7-7-4