SYSTEM T IM ER S
System > Timers >
Exit Time
This menu sets the exit time delay period for all areas on
the system. The exit timer starts when an area is armed in
the On and Part On modes. The keypad will sound an exit
warning tone while the exit timer is running.
time can be programmed between 0 and 255 seconds.
(*** System Wide Parameter ***)
1)
Press [MENU] + [7] + [2] + [0]. The keypad will display the
current Exit Time.
Exit Time
060 Seconds
Press 0-9 OK to SAVE
2)
Using the numeric keys, enter the required Exit Time in
seconds. Valid times are 0 - 255 seconds 0 = No Exit Time.
Press [OK] to save and exit or press [MENU] to exit without
3)
saving.
System > Timers >
Entry Time 1
(*** System Wide Parameter ***)
This menu sets the entry time delay for zones programmed as
entry delay 1 zones. Entry Time 1 is common for all areas on the
system.
When a zone programmed as Delay 1 is triggered, the entry
time will start and the keypad will sound an entry warning tone.
Entry Time 1 can be programmed between 0 and 255 seconds.
1)
Press [MENU] + [7] + [2] + [1]. The keypad will display the
current Entry Time 1 delay.
Bosch Security Systems 05/10 BLCC100I
Daylight Saving Ends
Turn Clock Back 1 hr
Sunday 4 April 2010
Sunday 3 April 2011
MENU 7-2-0
0
6
0
SECONDS
Exit delay
MENU 7-2-1
0
2
0
SECONDS
Solution 16
plus
Installation Manual
Entry Time 1
020 Seconds
Press 0-9 OK to SAVE
2)
Using the numeric keys, enter the required delay for Entry Time
1 in seconds. Valid times are 0 - 255 seconds 0 = No Entry Time.
3)
Press [OK] to save and exit or press [MENU] to exit without
saving.
System > Timers >
Entry Time 2
(*** System Wide Parameter ***)
This menu sets the entry time delay for zones programmed as
entry delay 2 zones. Entry Time 2 is common for all areas on the
system.
When a zone programmed as Delay 2 is triggered, the entry
time will start and the keypad will sound an entry warning tone.
Entry Time 2 can be programmed between 0 and 255 seconds.
1)
Press [MENU] + [7] + [2] + [2]. The keypad will display the
current entry time.
Entry Time 2
040 Seconds
Press 0-9 OK to SAVE
2)
Using the numeric keys, enter the required delay for Entry Time
2 in seconds. Valid times are 0 - 255 seconds 0 = No Entry Time.
Press [OK] to save and exit or press [MENU] to exit without
3)
saving.
System > Timers >
Part Entry Time
(*** System Wide Parameter ***)
This menu allows you to program the Part Mode Entry Delay
time also know as entry guard. When armed in Part Mode, all
active zones retain their normal functionality. ie. instant zones
will trigger instantly etc. The part entry timer allows all active
zones to have an entry delay when the the area is armed in part
mode regardless of their normal functionality.This can help to
prevent false alarms when people on site inadvertantly unseal
an active zone.
If a valid PIN code is not entered before the timer expires then
the alarm will trigger. Programming the entry guard time as
zero will disable this feature.
1)
Press [MENU] + [7] + [2] + [3]. The keypad will display the
current Part Entry time.
System Programming
MENU 7-2-2
0
4
0
SECONDS
MENU 7-2-3
0
6
0
SECONDS
11-5