T
he Solution 16
is capable of controlling up to 16 inputs
plus
in either hardwire or wireless configuration. Each input can
have its own unique name up to 16 characters to identify it on
the system for display and reporting purposes.
Under the commands menu you are able to view the status of
any input, bypass a zone, define which zones will operate in
chime mode, define which zones operate in part 2 mode and
reset smoke detectors.
There is a command called Zone Array that allows the installer
to view the condition of inputs in banks of 16. This is extremely
helpful when commissioning a system or fault finding.
There are numerous configurations for each hardwire input. The
end of line resistor can be configured to eliminate the need to
change the end of line resistors on a job when doing a change
over. Input zones can be setup as alarm only, alarm + tamper or
even split end of line.
For normally open contacts the system is wired exactly the
same as for normally closed but there is an option provided that
inverts the sealed state of a zone.
Address SW
Device
1
Solution Panel
CM104B Expander
OFF OFF OFF
Total Zones
Bosch Security Systems 05/10 BLCC100I
ZON E CO NFI G UR ATI O N TA BL ES
Single EOL
2
3
Zones
---
8
8
16
Table 20: Zone Configuration
Input Programming
When arming the system, all zones will be tested by default and
you may wish to turn this option off for certain zones so that you
don't continually alert the operator during arming.
The sensor watch feature lets you monitor zones to ensure that
they are working and detecting movement within a determined
programmable period.
Zones by default can be bypassed and you should disable
this option for zones you don't want to be able to bypass, for
example 24hr, fire, holdup or panic zone types.
The PGM input is a special input that can be configured to accept
data from a number of different RF receiver manufacturers or
simply be used as an keyswitch input.
The tamper options configure the system behaviour for cabinet
tamper alarms and also for the cabinet tamper of the peripheral
devices.
Alarm + Tamper
Physical Zone
Numbering
Zones
1 to 8
8
9 to 16
8
Split EOL
Physical Zone
Numbering
Zones
1 to 8
16
9 to 16
16
SECT ION 7
Physical Zone
Numbering
1 to 16
16
7-1