31-Pin Electrical Connections - Masterflex MFLX77112-10 Operating Manual

Ss b/t washdown digital pump drives with advanced connectivity
Table of Contents

Advertisement

Section 5: Service & Maintenance

31-PIN ELECTRICAL CONNECTIONS

CAUTION: Power must be turned off before connecting the external analog control
!
cable to prevent damage to the drive.
Contact Arrangements:
31-Pin
Description
No.
1
Speed Control Voltage Input (0–10 V)
2
Speed Signal Voltage Output (0–10 V)
3
Speed Control Current Input (0-20 mA)
4
Remote Start/Stop Input
5
Speed Control Input Ground Reference
6
Remote CW/CCW Input
7
Speed Signal Current Output (0-20 mA)
8
Remote Start/Stop, CW/CCW, Prime Grnd Ref.
9
Speed Signal Output Ground Reference
10
Tach Ground Reference
11
Motor Running Relay Output (N.O.)
12
Tach Output (Open Collector)
5-5
Masterflex SS B/T Washdown Digital Pump Drive with Advanced Connectivity
14
8
19
25
30
31
29
24
13
18
31-Pin
No.
13
14
15
16
17
18
19
20
21
22
23–31
3
1
2
7
Description
Motor Running Relay Common
Remote Prime Input
Open Head Relay Output (N.O.)
General Alarm Ready Common
Not Used
Local/Remote Relay Common
Open Head Relay Common
General Alarm Relay Output (N.O.)
Not Used
Local/RemoteRelay Output (N.O.)
Not Used
-
-
Masterflex