Section 3: Operation

TIME MODE

In Time Mode the pump will operate at a selected rpm and/or fl ow rate for a selected time and/or batch total.
At the completion of the selected time or batch total the pump will automatically stop.

Time Mode Run Screen

Th e Time Mode Run Screen is accessed by selecting TIME from the Mode Selection Screen.
A. Mode Name Banner
C. Cumulative Volume
G. Set Off Time
L. Flow Direction
A. MODE NAME BANNER: Tap the Mode Name Banner to return to the Mode Selection Screen.
B. EDIT: Tap to access the Time Mode Edit Screen. From the Time Mode Edit Screen changes can be made
to fl ow rate, fl ow units, tube size, tube calibration, on time, off time, and batch total.
C. CUMULATIVE VOLUME: Displays the current Cumulative Volume of fl uid that has been pumped. To
reset the cumulative volume: Press and hold CUMULATIVE VOLUME RESET
changes to zero.
D. BATCH TOTAL: Displays the number of dispenses that have been completed in the current batch. To
reset the batch total: Press and hold BATCH RESET
E. SET ON TIME: Displays the set dispense operation time.
F. ON TIME COUNTER: Displays a countdown of the set dispense time during operation.
G. SET OFF TIME: Displays the set duration of time the pump pauses between each dispense operation.
H. OFF TIME COUNTER: Displays a countdown of the set off time during operation.
I. FLOW RATE: Displays the current fl ow rate in the unit of measurement selected by the user.
J. PRIME: Press and hold to prime the pump drive (for further information see
on page 2-12).
K. START/STOP/PAUSE: During operation, the display will change from START
RESET
.
3-5
Masterflex SS B/T Washdown Digital Pump Drive with Advanced Connectivity
I. Flow Rate
J. Prime
N. Logout
B. Edit
D. Batch Total
E. Set On Time
F. On Time Counter
H. Off Time Counter
K. Start/Stop/Pause
M. Screen Lock
O. Settings
until the display changes to zero.
"Priming the Pump
until the display
Drive"
to PAUSE
STOP/
Masterflex