Masterflex Ethernet/Ip - Masterflex MFLX77112-10 Operating Manual

Ss b/t washdown digital pump drives with advanced connectivity
Table of Contents

Advertisement

Section 4: Communication Specification

MASTERFLEX ETHERNET/IP

Input data; 56 bytes of input data from pump to master.
Bytes
0-3
4
5
6
7
8 - 11
12 - 15
16 - 19
20 - 23
24 - 27
28 - 31
32 - 35
36 - 39
40 - 43
44 - 45
46
47
48
49
50 - 51
52
53
54
55
4-4
Masterflex SS B/T Washdown Digital Pump Drive with Advanced Connectivity
Data Type
Description
32-Bit INT
Pump Status
Bit 0: Status OK
Bit 1: Pump Running
Bit 2: Dispense Running
Bit 3: Tube Uncalibrated
Bit 4: Head Open
Bit 5: Reserved
Bit 6: Flow Direction CCW
Bit 7: Remote Control
Bit 8-31: Reserved
BYTE
Dispense Mode
BYTE
Tube Size
BYTE
Flow Units
BYTE
Reserved Pad
FLOAT
Cumulative Volume
FLOAT
Remaining Dispense Volume
FLOAT
Remaining Dispense On Seconds
FLOAT
Remaining Dispense Off Seconds
32- bit INT
Batch Count Current
32- bit INT
Batch Count Total
FLOAT
Minimum Flow Rate
FLOAT
Current Flow Rate
FLOAT
Maximum Flow Rate
16- bit INT
Remaining Dispense On Time Days
BYTE
Remaining Dispense On Time Hours
BYTE
Remaining Dispense On Time Minutes
BYTE
Remaining Dispense On Time Seconds
BYTE
Remaining Dispense On Time Tenths
16- bit INT
Remaining Dispense Off Time Days
BYTE
Remaining Dispense Off Time Hours
BYTE
Remaining Dispense Off Time Minutes
BYTE
Remaining Dispense Off Time Seconds
BYTE
Remaining Dispense Off Time Tenths
Masterflex