Adding a New Program: Volume Mode

To add a new Volume Mode program:
1. Tap NEW PROGRAM from the Mode Selection Screen. Th e New Program Screen will be displayed.
NOTE: If NEW PROGRAM is not displayed on the Mode Selection Screen tap SCROLL
additional pages.
2. Tap VOLUME. Th e Volume New Program Screen will be displayed.
3. Tap PROGRAM1. If required, delete the characters using the back arrow on the onscreen keypad and
then enter the desired program name (up to 8 characters).
4. Tap VOLUME. Th e Dispense Volume Screen will be displayed.
a. Tap VOLUME and enter the desired volume using the onscreen keypad. NOTE: If the volume of
fl uid is unknown the pump drive can record fl uid dispense volumes (for further information see
ume
Record" on page 3-12).
b. Tap RAMP UP
using the onscreen keypad.
c. Tap RAMP DOWN
(between 0 and 60 seconds) using the onscreen keypad.
d. Tap CONFIRM
gram Screen.
5. Tap INTERVAL TIME to set the amount of time the pump will pause between each operation. Th e
Interval Time Screen will be displayed. NOTE: If the interval time is set to 0 (zero) the pump drive will
require a start input (from either the touchscreen or a wired input) to start the next dispense.
a. Tap HR, MIN, SEC or TENTHS and enter the desired time using the onscreen keypad.
b. Tap CONFIRM
gram Screen.
6. Tap FLOW RATE. Th e Flow Rate Edit Screen will be displayed.
a. Tap UNITS to access the Flow Units Screen and select the desired fl ow unit from the available list.
b. Tap CONFIRM
c. Tap FLOW and enter the desired fl ow rate using the onscreen keypad.
d. Tap CONFIRM
gram Screen.
7. Tap SIZE. Th e Tube Size Screen will be displayed.
a. Select the desired tube size from the list of available options.
b. Tap CONFIRM
gram Screen.
8. Tap DIRECTION to select either clockwise
9. Tap BATCH TOTAL to adjust the number of dispenses in each batch cycle. Th e Batch Total Screen will
be displayed.
a. Enter the desired number of dispenses in a batch using the onscreen keypad. NOTE: If required, tap
INFINITE ∞ to select an infi nite number of dispense cycles. If infi nite is selected, the pump will run
3-19
Masterflex SS B/T Washdown Digital Pump Drive with Advanced Connectivity
to set the time the pump takes to reach full fl ow rate (between 0 and 60 seconds)
to set the time the pump takes to stop at the end of each dispense operation
to save or CANCEL
to save or CANCEL
to save or CANCEL
to save or CANCEL
to save or CANCEL
to discard changes and return to the Volume New Pro-
to discard changes and return to the Volume New Pro-
to discard changes and return to the previous screen.
to discard changes and return to the Volume New Pro-
to discard changes and return to the Volume New Pro-
or counterclockwise
to view
fl ow direction.