Masterflex I/P MFLX77603-20 Operating Manual

Masterflex I/P MFLX77603-20 Operating Manual

Rapid-load pump head

Advertisement

Quick Links

MASTERFLEX
®
I/P MFLX77603-20
(US & Canada only) Toll Free 1-800-MASTERFLEX • 1-800-637-3739
(Outside US & Canada) 1-847-381-7050
www.avantorsciences.com/masterflex • masterflex.tech@avantorsciences.com
®
®
OPERATING MANUAL:
®
RAPID-LOAD
PUMP HEAD
Model Nos.
MFLX77603-20
MFLX77603-22
MFLX77603-50 ATEX
MFLX77603-52 ATEX
®
I/P
®
®
®
A-1299-7519
Edition 02

Advertisement

Table of Contents
loading

Summary of Contents for Masterflex I/P MFLX77603-20

  • Page 1 OPERATING MANUAL: ® ® ® ® RAPID-LOAD PUMP HEAD Model Nos. MFLX77603-20 MASTERFLEX ® I/P MFLX77603-20 MFLX77603-22 MFLX77603-50 ATEX MFLX77603-52 ATEX A-1299-7519 Edition 02 (US & Canada only) Toll Free 1-800-MASTERFLEX • 1-800-637-3739 (Outside US & Canada) 1-847-381-7050 www.avantorsciences.com/masterflex • masterflex.tech@avantorsciences.com...
  • Page 2 Preface © 2023 Masterflex LLC. All rights reserved. ® ® ® MASTERFLEX , I/P RAPID-LOAD – Reg TM of Masterflex LLC C-FLEX, NORPRENE, PHARMED, TYGON—Reg TM Saint-Gobain Performance Plastics Corp. ® Trademarks bearing the symbol in this publication are registered in the U.S. and in other countries.
  • Page 3 ATEX or the NEC (National Electrical Code); including, but not limited to use with flammable liquids. Consult the factory for products suitable for these types of applications. ® ® ® Masterflex MASTERFLEX Rapid-Load Pump Head Operating Manual...
  • Page 4: Table Of Contents

    Technical Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 ® ® ® MASTERFLEX Rapid-Load Pump Head Operating Manual Masterflex...
  • Page 5 Mounting Holes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 MASTERFLEX ®...
  • Page 6: Introduction

    It is designed for optimal pumping in the clockwise direction. There are two mounting positions. Tubing entry and exit are either on the left side or right side of the pump when mounted on a MASTERFLEX I/P Drive. The pump will operate with any MASTERFLEX I/P drive with 580 oz-in (42 kg·cm) or more output torque.
  • Page 7: Setup And Operation

    Section 2 Pump Drive The I/P® Rapid-Load® Pump Head has a standard shaft interface to accommodate MASTERFLEX I/P Pump Drives. Pump drive must provide Compatibility 580 in-oz (42 kg·cm) torque. NOTE: These drives are usually designated as capable of driving two or more Pump Heads.
  • Page 8: Selecting Tubing

    Setup and Operation Selecting Tubing Pumps accept only MASTERFLEX I/P® Precision tubing sizes I/P 26, I/P 73, I/P 82 or I/P High-Performance tubing sizes I/P 70, I/P 88, I/P 89. Use only MASTERFLEX tubing that is surface-printed with the tubing designation.
  • Page 9: Operation

    (continued) 3. Insert the MASTERFLEX tubing inside tubing guide and around rotor, depress tubing retainer and insert tubing. Pull tubing snug against roller with the ends of the tubing extending out of the tubing entrance and tubing exit as shown in Figure 2-3 and release tubing retainer.
  • Page 10: Maintenance

    Replacement Occlusion Kit, Thin Wall (I/P Size 26, 73, 82) 77603-87 Replacement Occlusion Kit, Thick Wall (I/P Size 70, 88, 89) 77603-88 (F or G) (C or D) Figure 3-1 . Exploded View of Pump ® ® ® 3-1 MASTERFLEX Rapid-Load Pump Head Operating Manual Masterflex...
  • Page 11: Cleaning Pump Head

    Section 3 Maintenance Cleaning Pump Head Use mild detergent with water to clean the pump and rotor assembly. Do not immerse nor use excessive fluid. ® ® ® Masterflex MASTERFLEX Rapid-Load Pump Head Operating Manual...
  • Page 12: Specifications

    ** 70, 88, and 89 tubing are for use only with the MASTERFLEX ® ® Rapid-Load ® Pump Head designed for I/P High-Performance Precision (thick wall) tubing and any MASTERFLEX I/P drive capable of running two or more Pump Heads . ® ® ® 4-1 MASTERFLEX...
  • Page 13 ‡ Use in this temperature range for continuous duty operation with no decrease in performance or product life . Pump Heads will work outside this range with some possible reductions in performance or product life . ® ® ® Masterflex MASTERFLEX Rapid-Load Pump Head Operating Manual...
  • Page 14: Warranty

    Warranty, Product Return and Section 5 Technical Assistance Warranty Use only MASTERFLEX precision tubing with MASTERFLEX pumps to ensure optimum performance. Use of other tubing may void applicable warranties. This product is warranted against defects in material or workmanship, and...
  • Page 15: Product Return

    Any damages resulting from improper packaging are your responsibility. Technical Assistance If you have any questions about the use of this product, contact the Manufacturer or authorized seller. ® ® ® Masterflex MASTERFLEX Rapid-Load Pump Head Operating Manual...
  • Page 16 ® ® ® *EN809 manufactured by: US & Canada only Masterflex LLC Toll Free 1-800-MASTERFLEX | 1-800-637-3739 28092 W Commercial Avenue, Barrington, IL 60010 Outside US & Canada masterflex.tech@avantorsciences.com www .avantorsciences .com/masterflex 1-847-381-7050...

Table of Contents