Synchronous encoder axis monitor data (Bit device)

Symbol
Monitor item
St.320
Synchronous
encoder axis setting
valid flag
St.321
Synchronous
encoder axis
connecting valid
flag
St.322
Synchronous
encoder axis
counter enable flag
St.323
Synchronous
encoder axis
current value setting
request flag
St.324
Synchronous
encoder axis error
detection flag
St.325
Synchronous
encoder axis control
complete flag
[St.320] Synchronous encoder axis setting valid flag (R: M38640+16n/Q: M10440+10n)
At Multiple CPU system power supply ON, this flag turns ON when the setting of the synchronous encoder axis is valid. It is
turned OFF when the setting is invalid.
[St.321] Synchronous encoder axis connecting valid flag (R: M38641+16n/Q:
M10441+10n)
At Multiple CPU system's power supply ON, this flag turns ON when the synchronous encoder connection is valid.
This flag turns OFF when the connection is invalid.
When setting an incremental synchronous encoder, this flag turns ON simultaneously the Multiple CPU system power supply
turns ON regardless of the actual encoder connection.
[St.322] Synchronous encoder axis counter enable flag (R: M38642+16n/Q:
M10442+10n)
This flag turns ON when input from the synchronous encoder is enabled.
If the counter disable control is executed, it is turned OFF, and input from the synchronous encoder becomes invalid. If the
counter enable control is executed, it is turned ON, and input from the synchronous encoder becomes valid. Just after the
synchronous encoder is valid to connect, the status is ON (enable).
Storage details
This flag turns ON when the
setting of the synchronous
encoder axis is valid.
This flag turns ON when the
synchronous encoder axis
connection is valid.
This flag turns ON when input
from the synchronous encoder is
enabled.
This flag turns ON when the
current value of synchronous
encoder axis is not set.
This flag turns ON when an error
occurs for the synchronous
encoder axis.
This flag turns ON at the
completion of synchronous
encoder axis control.
Monitor value
ON: Setting valid
OFF: Setting invalid
ON: Connection valid
OFF: Connection invalid
ON: Counter enable
OFF: Counter disable
ON: Current value setting request
OFF: Current value setting not
requested
ON: Error occurred
OFF: No error
ON: Control completed
OFF: Control not completed
Refresh
Device No.
cycle
MELSEC
Q series
iQ-R Motion
Motion
device
compatible
assignment
device
assignment
At power ON
M38640+16n
M10440+10n
Operation
M38641+16n
M10441+10n
cycle
M38642+16n
M10442+10n
M38643+16n
M10443+10n
Immediate
M38644+16n
M10444+10n
M38646+16n
M10446+10n
4 INPUT AXIS MODULE
4.3 Synchronous Encoder Axis
4
81