*1 Operating system software version
• Bit device setting
Set a number in a unit of 32 points at the start of the device.
The status of synchronous control is stored in the set devices as follows.
Offset
*1
"07" or later
"05" or earlier
+0
+0
+1
+1
to
to
+31
+31
+32
+33
to
+63
*1 Operating system software version
Item
*1
[St.380] Synchronous control Axis 1
[St.380] Synchronous control Axis 2
to
[St.380] Synchronous control Axis 32
[St.380] Synchronous control Axis 33
[St.380] Synchronous control Axis 34
to
[St.380] Synchronous control Axis 64
Device
MELSEC iQ-R Motion
device assignment
M40000
M40001
to
M40031
M40032
M40033
to
M40063
8 AUXILIARY AND APPLIED FUNCTIONS
8.4 Multiple CPU Advanced Synchronous Control
Q series Motion compatible
device assignment
M10880
M10881
M10911
179