96 Motor control and I/O board (RMIO)
Relay outputs
Switching capacity
Minimum continuous
current
Maximum continuous
current
Isolation test voltage
DDCS fiber-optic link
24 VDC power input
Voltage
Typical current
consumption (without
optional modules)
Maximum current
consumption
The terminals on the RMIO board as well as on the optional modules attachable to the board fulfill the
Protective Extra Low Voltage (PELV) requirements stated in EN 50178 provided that the external
circuits connected to the terminals also fulfill the requirements and the installation site is below
2000 m (6562 ft). Above 2000 m (6562 ft), see page 67.
Three programmable relay outputs
8 A at 24 V DC or 250 V AC, 0.4 A at 120 V DC
5 mA rms at 24 V DC
2 A rms
4 kV AC, 1 minute
With optional communication adapter module RDCO. Protocol: DDCS
(ABB Distributed Drives Communication System)
24 V DC ± 10%
250 mA
1200 mA (with optional modules inserted)