ABB ACS800 Series Application Manual

ABB ACS800 Series Application Manual

Industrial drives, safe torque off function (+q967)
Hide thumbs Also See for ACS800 Series:
Table of Contents

Advertisement

ABB INDUSTRIAL DRIVES
ACS800-01/U1/04/04LC/04M/U4/11/U11/14/31/U31/104/104LC
Safe torque off function (+Q967)
Application guide

Advertisement

Table of Contents
loading

Summary of Contents for ABB ACS800 Series

  • Page 1 — ABB INDUSTRIAL DRIVES ACS800-01/U1/04/04LC/04M/U4/11/U11/14/31/U31/104/104LC Safe torque off function (+Q967) Application guide...
  • Page 2 You can find manuals and other product documents in PDF format on the Internet. Document library on the Internet See section on the inside of the back cover. For manuals not available in the Document library, contact your local ABB representative.
  • Page 3 Application guide ACS800-01/U1/04/04LC/04M/U4/11/U11/14/31/U31/104/104LC Safe torque off function (+Q967) Table of contents 3. Installation 4. Start-up and use  2020 ABB Oy. All Rights Reserved. 3AUA0000063373 Rev J EFFECTIVE: 2020-06-11...
  • Page 5: Table Of Contents

    Table of contents 1. Introduction to the manual Contents of this chapter ..........7 Applicability .
  • Page 6 4. Start-up and use Contents of this chapter ..........29 Start-up and acceptance test .
  • Page 7: Introduction To The Manual

    Introduction to the manual 7 Introduction to the manual Contents of this chapter This chapter describes the manual in short and gives some general information for the reader. Applicability The manual applies to the ACS800-01/04/04LC/04M/11/14/31/104/104LC and ACS800-U1/U4/U11/U31 drives and inverter modules which have the option +Q967: Safe torque off (STO).
  • Page 8: Target Audience

    8 Introduction to the manual WARNING! (With permanent magnet motors only) In case of a multiple IGBT power semiconductor failure, the inverter system can produce an alignment torque which maximally rotates the motor shaft by 180/p degrees regardless of the activation of the Safe torque off function. p denotes the number of pole pairs. WARNING! Read and obey all safety instructions in the drive hardware manual.
  • Page 9: Abbreviations

    Introduction to the manual 9 Abbreviations Abbreviations used in this manual are listed below. Abbr. Reference Description ASTO Safe torque off board Cat. EN ISO 13849-1 Category. Classification of the safety-related parts of a control system in respect of their resistance to faults and their subsequent behavior in the fault condition, and which is achieved by the structural arrangement of the parts, fault detection and/or by their reliability.
  • Page 10 10 Introduction to the manual...
  • Page 11: Option Description

    Option description 11 Option description Contents of this chapter This chapter describes the Safe torque off (STO) function of the drive and inverter modules and lists the indications and response times of the Safe torque off function. Description The Safe torque off function can be used, for example, to construct safety or supervision circuits that stop the inverter in case of danger (such as an emergency stop circuit).
  • Page 12: Operation Principle

    12 Option description Example diagram of STO in R8i module with safety relay INVERTER MODULE R8i The STO function corresponds to Prevention of unexpected start-up as specified by EN ISO 14118:2018 (ISO 14118:2017), and Uncontrolled stop (stop category 0) as specified in EN/IEC 60204-1.
  • Page 13: Sto Status Indications

    Option description 13 The table below describes the operation of the STO function in detail depending on: • status of the STO inputs • the fault or warning START INHIBI (see chapter Maintenance and fault tracing). START INHIBI Status of STO inputs When drive is How the STO function operates indication...
  • Page 14: Sto Function Activation And Indication Response Times

    14 Option description STO function activation and indication response times Module response times only  STO activation and indication response times Typical response time Maximum response time 2 ms 20 ms STO activation response time 1.5 ms STO indication response time STO activation response time = delay between de-energizing the STO input and switching off the drive/ inverter output bridge STO indication response time = delay between de-energizing the STO input and indication of STO input de-...
  • Page 15: Installation

    115 V supply voltage, it is not possible to use it with Safe torque off function (option +Q967) or vice versa. Note this when using spare parts. Note: The Safe torque off function can be installed afterwards (that is, after the factory assembly) to drive modules. Contact ABB Drives Service for further information. Connections STO input ...
  • Page 16: Activation Switch

    3AUA0000067826 WARNING! Drive modules, frame sizes R2...R6: For connecting the ASTO board and the module, use only the wire kits delivered by ABB. If you use other cables or modify the cables, you may cause a malfunction of the drive.
  • Page 17: Example Wiring Diagrams

    Installation 17 Example wiring diagrams Connect the cables as shown in the diagram below. For more information on the components, see chapter Technical data. STO connections without safety relays  The following diagrams show the STO connections without safety relays in: •...
  • Page 18: Frame Sizes R2 To R6

    18 Installation Frame sizes R2 to R6 RINT-XXXX / GINT-XXXX 3AUA0000072542 Frame sizes R7 and R8 3AUA0000072272...
  • Page 19: Frame Sizes R2I To R4I

    Installation 19 Frame sizes R2i to R4i 3AUA0000077408 Frame size R5i 3AUA0000077456...
  • Page 20: Frame Size R7I

    20 Installation Frame size R7i 3AUA0000077458 Frame size R8i 3AUA0000077457...
  • Page 21: Liquid-Cooled Modules Of Frame Sizes R7I And R8I

    Installation 21 Liquid-cooled modules of frame sizes R7i and R8i 3AUA0000077142...
  • Page 22: Sto Connections With Safety Relays

    22 Installation STO connections with safety relays  The following diagrams show examples of STO connections with safety relays for: • single drives R2-R6 and R7-R8 (page 22) • inverter modules R2i-R4i, R5i, R7i and R8i (pages 24-27) • multiple drive/inverter modules or inverter units (page 28). Note: The safety relay is not included in the delivery when the drive is equipped with option +Q967.
  • Page 23: Frame Sizes R7 And R8

    Installation 23 Frame sizes R7 and R8 3AUA0000078208...
  • Page 24: Frame Sizes R2I To R4I

    24 Installation Frame sizes R2i to R4i INVERTER MODULE R2i, R3i AND R4i 3AUA0000071122...
  • Page 25: Frame Size R5I

    Installation 25 Frame size R5i INVERTER MODULE R5i 3AUA0000071141...
  • Page 26: Frame Size R7I

    26 Installation Frame size R7i INVERTER MODULE R7i 3AUA0000071142...
  • Page 27: Frame Size R8I

    Installation 27 Frame size R8i INVERTER MODULE R8i 3AUA0000071143...
  • Page 28: Connecting Several Drive/Inverter Modules Or Inverter Units To One Safety Relay

    28 Installation Connecting several drive/inverter modules or inverter units to one safety relay In the example, R8i modules are used, but the same principle applies to any frame size. INVERTER MODULE R8i INVERTER MODULE R8i 3AUA0000096632...
  • Page 29: Start-Up And Use

    Start-up and use 29 Start-up and use Contents of this chapter This chapter contains the start-up and acceptance test procedure for the Safe torque off function and gives instructions for its use. Start-up and acceptance test To ensure the safe operation of a safety function, validation is required. The final assembler of the machine must validate the function by performing an acceptance test.
  • Page 30: Acceptance Test Reports

    30 Start-up and use Acceptance test reports  You must store the signed acceptance test reports in the logbook of the machine. The report must include, as required by the referred standards: • description of the safety application (including a figure) •...
  • Page 31: Use

    Start-up and use 31 Note: The drive/inverter indications are described in more detail in section STO status indications on page 13. 1. Open the activation switch, or activate the safety functionality that is wired to the STO connection. 2. STO inputs on the ASTO board de-energize, and the ASTO board cuts off the control voltage from the drive/inverter IGBTs.
  • Page 32 32 Start-up and use...
  • Page 33: Maintenance And Fault Tracing

    If any wiring or component change is needed after start up, follow the test given in section Acceptance test procedure (page 30). Use only spare parts approved by ABB. Record all maintenance and proof test activities in the machine logbook. Proof test interval ...
  • Page 34: Competence

    Safe torque off is check power supply at ASTO board input active. terminals. Replace ASTO board. Any failures of the Safe torque off function must be reported to ABB.
  • Page 35: Technical Data

    Technical data 35 Technical data Contents of this chapter This chapter contains the technical details of the ASTO-11 and ASTO-21 boards, the safety data for the STO components and example information of safety relays and activation switches. It also lists the related standards and directives, and contains declarations of conformity with the European Machinery Directive.
  • Page 36: Asto Board According To Frame Size Of The Module

    36 Technical data Note: Supply from semiconductor safety output with test pulse may lead to unnecessary trips. Contact ABB for further information. ASTO board according to frame size of the module Frame size ASTO-11/21 board R2i…R5i ASTO-11 R2…R6 ASTO-11 R7i…R8i ASTO-21 R7…R8...
  • Page 37: Sto Safety Relay Type

    IEC 61508 and/or EN/ISO 13849-1 Example 1 Simple SIL3 approved safety relay Type and manufacturer DOLD LG 5925.48/60 AC/DC 24 V ABB BT50 24DC Approvals SILCL 3 according to EN 62061 and PL e according to EN ISO 13849-1 Example 2 Programmable safety logic...
  • Page 38: Multiples Of Frame Size R8I

    38 Technical data Multiples of frame size R8i  Above values for frame sizes R7/R7i/R8/R8i apply for the multiples of frame size R8i, except for values of PFH, PFD and MTTF . These values are listed below. MTTF Frame size (1/h) = 2 a = 5 a...
  • Page 39: Related Standards And Directives

    Technical data 39 Related standards and directives The Safe torque off function of the inverter complies with these standards: Standard Name EN 60204-1:2016 Safety of machinery – Electrical equipment of machines – Part 1: General IEC 60204-1:2006 + A1:2009 requirements + AC:2010 IEC 61508-1:2010 Functional safety of electrical/electronic/programmable electronic safety-...
  • Page 40: Declarations Of Conformity

    40 Technical data Declarations of Conformity...
  • Page 41 Technical data 41...
  • Page 42 42 Technical data...
  • Page 43 Technical data 43...
  • Page 44 44 Technical data...
  • Page 45: Further Information

    Product and service inquiries Address any inquiries about the product to your local ABB representative, quoting the type designation and serial number of the unit in question. A listing of ABB sales, support and service contacts can be found by navigating to abb.com/searchchannels.
  • Page 46 © Copyright 2020 ABB. All rights reserved. Specifications subject to change without notice.