84 Installation of the AGPS board (Prevention of unexpected start-up, +Q950)
WARNING! The supply voltage for the AGPS board is 115...230 V AC. If the
board is supplied with 24 V DC, the board is damaged and it needs to be
replaced.
See
page
25
for the location of terminal block X41 in the drive
page
85
for the circuit diagram
page
86
for the dimensions of the AGPS board
AGPS-11C (option +Q950)
Note: The maximum cable length between AGPS terminal block X2 and the drive
terminal block is 10 m (33 ft).
Connect the AGPS board as follows:
Remove the enclosure cover by undoing the fixing screws (1).
Ground the bottom plate of the enclosure or via terminal X1:1 of the AGPS board.
Connect the cable delivered with the kit between terminal block X2 of the AGPS
board (2) and drive terminal block X41.
WARNING! Use only the AGPS cable delivered with the kit. Using another
cable or modifying the cable may cause a malfunction of the drive and the
safety function.
Connect a cable between connector X1 of the AGPS board (3) and the 115...230 V
source.
Attach the enclosure cover with screws.
(page 129) for the technical data of the board.