Chapter 10 Serial Port Configuration
10.1 Set RS-485
Set RS-485 parameters if the device needs to be connected to other peripheral devices controlled
by RS-485 serial port.
Before You Start
The corresponding device has been connected via the RS-485 serial port.
Steps
Note
The number of available RS-485 serial port varies with different models.
1. Go to Configuration → System → System Settings → Serial Port → RS-485.
2. Set Baud Rate, Data Bit, Stop Bit, etc.
Note
The parameters should be same with those of the connected device.
3. Set Work Mode.
Application Trigger
Select it when the signal trigger devices (such as radar) are connected to the RS-485 serial
port of the device.
Transparent Channel
Select it when the other peripheral devices are connected to the RS-485 serial port of the
device for communication transmission.
GPS
The GPS devices are connected to the RS-485 serial port of the device for receiving location
data.
4. Click Save.
Tyre and Axle Recognition Unit User Manual
Figure 10-1 Set RS-485
47