6-16. Remote Voltage/Amperage Control
1
2
6-17. Engine Auto-Speed
Engine Auto-Speed
When in Auto-Speed, unit will idle at 2400
RPM. Speed is determined based on load
requirement.
OM-291102 Page 46
™
Any auxiliary power load increases engine
speed to 3600 RPM on models not equipped
with Excel power.
RPM for a weld load is based on preset and
then adjusted based on actual load.
1 Remote Receptacle RC41
Connect optional remote voltage/amperage
(V/A) control to Remote Control (RC) recep-
tacle (see Section 5-9).
2
Adjust Control/Select Button
�
Remote weld setting must be set to AU-
TO. If set to OFF, remote connection
will be ignored.
With remote control connected, weld output
in Stick or TIG is determined by a combina-
tion of front panel and remote control volt-
age/amperage settings. In MIG, weld output
is controlled through remote control only.
Connect remote V/A control to 14 pin remote
receptacle.
Set process (Stick shown).
Set V/A control to 160A.
Adjust remote V/A control (stick welding
only).
Min 30A DC; Max 160A DC
Battery charge will charge at idle, and in-
crease to 3600 RPM for jump starting.
Any combination of loads will increase en-
gine speed to 3600 RPM.