Remote Voltage/Amperage Control - Miller Big Blue 400 PX CE Owner's Manual

Hide thumbs Also See for Big Blue 400 PX CE:
Table of Contents

Advertisement

6-4. Remote Voltage/Amperage Control

1
In Example:
Min = 20 A DC
Max = 205 A DC
Connect Remote
Control To Remote
Receptacle RC14
Connect Remote
Control To Remote
Receptacle RC14
Set TIG or STICK Process
Set WIRE Process
1
Remote 14 Receptacle RC14
Connect optional remote control to RC14 (see
Section 5-11).
.
When a remote control is connected to the
Remote receptacle, the Auto Sense Re-
mote feature automatically switches volt-
age/amperage control to the remote con-
trol. When a device is connected to the Re-
mote receptacle, remote voltage/amper-
age control is always available regardless
of the position of the Process/Contactor
switch.
Adjust Optional Remote
Control to 100%
Max (205 A DC)
Adjust Optional Remote
Control to desired
weld output
Set V/A Control
To Desired Maximum
Weld Output Using Weld
Meters
Min (20 A DC)
Adjust Optional Remote
Control to desired
weld output
Weld meters will always
show the combined main
and remote control setting
and machine welds at
nominal output setting of
the meter.
Weld meters show preset
output when not welding.
0774 / Ref.229 747-B / 804 630-A
OM-229 979 Page 33

Advertisement

Table of Contents
loading