7-3.

Connecting Installed Battery To Optional Battery Charge Receptacle

Stop welder/generator engine.
Before charging battery, check po-
larity of battery posts. If battery Neg-
ative (−) post is grounded to chassis
(most vehicles), connect charger
Positive (+) cable to Positive (+) un-
grounded post of battery. Connect
charger Negative (−) cable to vehicle
engine block or heavy gauge metal
part of frame (and away from bat-
tery). If Positive (+) post is grounded
to chassis, connect charger Nega-
tive (−) cable to Negative (−) un-
grounded post of battery. Connect
charger Positive (+) cable to vehicle
chassis or engine block (and away
from battery).
OM-291102 Page 50
3
1
2
Battery will not charge if it is com-
pletely dead. This happens at 1 volt.
1 Battery Positive (+) Terminal
2 Battery Negative (−) Terminal
Obtain Battery Charge/Jumper Cable Kit
300422 or equivalent.
3 Red (Positive) Charging Cable
4 Black (Negative) Charging Cable
5 Battery Charge Plug
6 Battery Charge Receptacle
4
5
6
Negative Post Grounded
If battery Negative (−) post is grounded to
chassis, connect red (Positive) battery
charging cable to battery Positive (+) post.
Connect black (Negative) battery charging
cable to engine block or heavy gauge metal
part of frame (and away from battery).
Connect Battery Charge plug to Battery
Charge receptacle.