Miller Trailblazer 330 Diesel Owner's Manual page 73

Table of Contents

Advertisement

LCD Message
Inverter Current Sensor Error
- Have Power Module
Serviced
Inverter Plus 15V Error -
Have Power Module
Serviced
Inverter Plus 5V Error - Have
Power Module Serviced
Inverter Plus 12V Error -
Check Battery Voltage
Inverter Minus 15V Error -
Have Power Module
Serviced
Inverter Connector Error -
Have Power Module
Serviced
Boost LIN Communication
Error - Have Power Module
Serviced
Inverter LIN Communication
Error - Have Power Module
Serviced
Inverter Thermistor Open Er-
ror - Have Power Module
Serviced
Inverter Thermistor Short Er-
ror - Have Power Module
Serviced
Inverter Over Temp Error -
Wait For Temp To Drop
14 Pin Remote Removed
During Weld - Check 14 Pin
Connection
Spool Gun Not Connected -
Connect Spool Gun
Spool Gun Motor Error -
Have Power Module
Serviced
Polarity Reversing Error -
Have Unit Serviced
Inverter Control Comm Error
- Have Power Module
Serviced
Batt Charge Error - Check
Charge Voltage
Batt Read Open Error -
Check Battery Connection
Batt Check Open Error -
Check Battery Connection
Batt Charge Check Error -
Bad Battery Replace Battery
Batt Jump Start Timeout Er-
ror - Jump Start Timer
Expired
Batt Final Check Error - Bad
Battery Replace Battery
Help Code
Problem
ERR DE00
Output Current Sensor not
reading correctly.
ERR HN00
Inverter Control board +15V
supply out of range.
ERR HN01
Inverter Control board +5V
supply out of range.
ERR HN02
Battery voltage outside of
range.
ERR HN03
Inverter Control board -15V
supply out of range.
ERR DE01
Inverter Control board does
not have inverter connector
plugged in.
ERR NC00
Inverter Control board boost
LIN communication fault.
ERR NC01
Inverter Control board inver-
ter LIN communication fault.
ERR DH00
Inverter Control board ther-
mistor open.
ERR DH01
Inverter Control board ther-
mistor shorted.
ERR DH02
Inverter Control board ther-
mistor overtemp.
ALRT RE00
Lost 14 pin remote command
during weld.
ALRT WE00
Spool gun not connected.
ERR WK00
Spool gun motor fault.
ERR LL00
Polarity Reversing contactor
stuck in incorrect polarity.
ERR NC02
Inverter Control board com-
munication fault between in-
verter and weld micro.
ERR BP00
Battery charge set to wrong
voltage.
ERR BU00
Battery is disconnected or re-
verse connected.
ERR BU01
Battery is disconnected.
ERR BE00
Not enough voltage or no
current flow during battery
check.
ERR BE01
Battery charging at more
than 155A for over 20
seconds.
Battery charge current at 0 or
less current for over 40
seconds.
ERR BE02
Voltage has fallen below fault
level after charging.
Always check unit before applying power. See Pre-Power Checks.
Possible Cause
Indicates malfunction of out-
put current sensor.
Indicates malfunction of
power supplies on inverter
control board.
Indicates malfunction of
power supplies on inverter
control board.
Low battery voltage.
Indicates malfunction of
power supplies on inverter
control board.
Indicates malfunction in pri-
mary power circuit of unit.
Indicates malfunction of com-
munication systems.
Indicates malfunction of com-
munication systems.
Indicates a malfunction in
thermal protection circuitry.
Indicates a malfunction in
thermal protection circuitry.
Indicates unit has
overheated.
Remote disconnected.
Spool gun not connected.
High current detected in
spool gun motor circuit.
Stuck contactor.
Indicates malfunction of com-
munication systems.
Incorrect battery charge volt-
age selected.
Disconnected battery.
Disconnected battery.
Bad battery.
Boost charge timer expired.
Battery not drawing current,
timer expired.
Bad battery.
Potential Solution
Contact a Factory Authorized
Service Agent.
Contact a Factory Authorized
Service Agent.
Contact a Factory Authorized
Service Agent.
Charge battery.
Contact a Factory Authorized
Service Agent.
Contact a Factory Authorized
Service Agent.
Contact a Factory Authorized
Service Agent.
Contact a Factory Authorized
Service Agent.
Contact a Factory Authorized
Service Agent.
Contact a Factory Authorized
Service Agent.
Unit has shut down to allow
fan to cool it. Operation will
continue when unit has
cooled.
Reconnect remote.
Check spool gun connection.
Check spool gun connector
and cable. Switch process or
power cycle unit to clear er-
ror. If issue persists, contact
a Factory Authorized Service
Agent.
Contact a Factory Authorized
Service Agent.
Contact a Factory Authorized
Service Agent.
Select charge voltage that
matches battery.
Check battery connection.
Check battery connection.
Check battery.
Check load on battery.
Check connection to battery.
Replace battery.
OM-291102 Page 69

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trailblazer 330

Table of Contents