LCD Message
Batt Final Check Battery Er-
ror - Bad Battery Replace
Battery
Batt Charge Timer Expired
Error - Wait For Process To
Start Again
Batt Charge Check Connec-
tion - Check Battery
Connection
Batt Charge Over Voltage Er-
ror - Check Battery, Discon-
nect Clamp To Clear
Control Board Communica-
tion Error - Cycle Power
Software Invalid or Mismatch
- Update Software
Smart Accessory Bind Error -
Smart Accessory Not Cur-
rently Supported, Disconnect
OM-291102 Page 70
Help Code
Problem
ERR BE03
Too many retries on battery
charge final test.
ERR BX00
Battery charging past 13.5
hours.
ALRT BN00
Battery connection lost or po-
larity incorrect.
ERR BV00
24V Battery when in 12V
charge.
High voltage detected while
charging.
ERR SA01
CAN communication timeout
on control board.
ERR SA00
Different software versions
among PC boards.
ERR ZM00
Smart Feeder/Heater not
supported currently for this
product.
Always check unit before applying power. See Pre-Power Checks.
Possible Cause
Bad battery.
Battery charge time expired.
Battery connection lost or
connected in reverse.
Incorrect battery charge volt-
age selected.
Battery not taking charge.
Indicates issue with CAN
communication between
boards.
Different software versions
among PC boards.
Smart Feeder/Heater not
supported currently for this
product.
Potential Solution
Replace battery.
Start battery charge process
again if more time needed.
Check battery connection.
Disconnect clamps from bat-
tery. Select charge voltage
that matches battery. Recon-
nect and try again.
Contact a Factory Authorized
Service Agent.
Contact a Factory Authorized
Service Agent.
Disconnect Smart Accessory
from power source.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trailblazer 330