6-5. Remote Voltage/Amperage Control

1
In Example:
Min = 20 A DC
Max = 205 A DC
Connect Remote
Control To Remote
Receptacle RC14
Connect Remote
Control To Remote
Receptacle RC14
OM-244 620 Page 34
Set TIG or STICK Process
Set WIRE Process
1
Remote 14 Receptacle RC14
Connect optional remote control to RC14 (see
Section 5-12).
.
When a remote control is connected to the
Remote receptacle, the Auto Sense Re-
mote feature automatically switches volt-
age/amperage control to the remote con-
trol. When a device is connected to the Re-
mote receptacle, remote voltage/amper-
age control is always available regardless
of the position of the Process/Contactor
switch.
Turn Remote Control On. Ad-
just Optional Remote
Control to 100%
Adjust Optional Remote
Control to desired
weld output
Set V/A Control
To Desired Maximum
Weld Output Using Weld
Meters
Max (205 A DC)
Min (20 A DC)
Adjust Optional Remote
Control to desired
weld output
Weld meters show preset
output when not welding.
0774 / Ref.246 345-B / Ref. 907 428−1