Remote Voltage/Amperage Control - Miller Big Blue 400 Eco Pro CC Owner's Manual

Table of Contents

Advertisement

6-3. Remote Voltage/Amperage Control

1
Example: Combination Remote Voltage Control
Connect Remote
Control To Remote
Receptacle RC14
Example: Combination Remote Amperage Control (TIG)
Connect Remote
Control To Remote
Receptacle RC14
OM-247 432 Page 32
Set Process
Set Process
Mid-Range: About 250 A
1
Remote 14 Receptacle RC14
Connect optional remote control to RC14 (see
Section 5-12).
.
Remote controls requiring 24 volts AC con-
nected to the receptacle do not operate
when the Engine Control switch is in the
350-500 Amp position.
.
When a remote control is connected to the
Remote receptacle, the Auto Sense Re-
mote feature automatically switches volt-
age/amperage control to the remote con-
trol. When a device is connected to the Re-
mote receptacle, remote voltage/amper-
age control is always available regardless
of the position of the Process switch.
V/A Control setting does
not matter
Set V/A Control
In Example:
Process = Remote CV
Min = 16 V DC
Max = 40 V DC
Max (40 V DC)
Min (16 V DC)
Adjust Optional Remote Control
In Example:
Process = Remote TIG
Min = 20 A DC
Max = About 250 A DC
Max (250 A DC)
Min (20 A DC)
Adjust Optional Remote Control
0774 / Ref.287 125−A / Ref 804 444−A