6-4.

System Settings Screen

System Settings Item
Voltage Reducing Device
Cable Length Compensation

Weld Lead Calibration

Cable Size*
Cable Length*
Screen Brightness
* Only visible if WLC is Enabled.
Weld Lead Calibration provides an increase in arc voltage to help offset the voltage drop based off of inputs of weld cable length and
diameter.
6-5.
Weld Lead Calibration
Refer to Section 6-4 for enabling Weld Lead Calibration (WLC)
Use of Auto-Set requires WLC or CLC to be enabled.
WLC is a method for overcoming voltage drop when using long cable runs. WLC uses estimated values for the voltage drop based on the ca-
ble size and total length of the positive and negative cables. It provides a voltage increase from the power source to achieve a voltage at the
wire feeder near the display set point.
Factors that affect WLC are the age and condition of your weld cables and the amount of connections used.
OM-291102 Page 36
Selectable Item Option
Enabled / Disabled
Enabled / Disabled
Enabled / Disabled
2, 1, and 1/0 to 4/0
10 to 500
1–10
To change System Settings:
� Rotate Adjust Control/Select button to
select a setting.
� Press Adjust Control/Select button on
desired setting.
� Rotate Adjust Control/Select button to
update the setting.
� Press Adjust Control/Select button to
save the setting, or press the Back but-
ton to discard setting change.
� Press Back button to return to Home
screen.
Default Setting
Enable/Disables voltage reducing device
Disabled
Enables the Cable Length Compensation
Disabled
Enables the Weld Lead Calibration (see Sec-
Enabled
2/0
Sets the cable size for Weld Lead Calibration.
Sets the total length of positive and negative
250
cables for Weld Lead Calibration.
10
Description
(see Section 6-7).
(see Section 6-6).
tion 6-5).
Sets screen brightness.