table 7-8 PID Parameter Description
Parameter
PID Recovery
Clear PID alarm
PID Scheme
AFCI Parameters
The AFCI function may not be applicable in some areas. Please consult SUN-
GROW for details.
Tap "Settings→Operation Parameters→AFCI Parameters" to enter the corresponding
screen, on which you can set "AFCI Parameters".
Regular Parameters
Tap "Settings→Operation Parameters→Regular Parameters" to enter the corresponding
screen, on which you can set "Regular Parameters".
figure 7-14 PID Parameters
Description
Enable/Disable the PID night recovery function. Once enabled, it
works between 22:00 pm and 5:00 am by default.
If ISO impedance abnormality or PID function exception is de-
tected during running of the PID function, the inverter reports a
PID abnormity and reminds the user to take corresponding meas-
ures. Clear the alarm report via this parameter once the problems
are handled.
Apply negative or positive voltage.
figure 7-15 AFCI Setting