6 Commissioning
Step 2 Close the AC circuit breaker between the inverter and the grid.
Step 3 Install the iSolarCloud App, see
Step 4 Set initial protection parameters via the iSolarCloud App when the inverter is connected to
the grid for the first time (see Step 4 in
diation and grid conditions meet requirements, the inverter normally operates.
Step 5 The home page is automatically displayed when the setting is completed. The indicator is
steady blue, and the inverter is in grid-connected operation.
- - End
6.3

Optimizer Physical Layout (Optional)

If PV modules are installed and optimizers are configured, check to ensure that all devi-
ces are reliably installed.
Remove QR code labels from the optimizers and attach them to corresponding square
cells on the physical layout.
Please refer to the optimizer user manual for details of the optimizer physical layout.
For details about plant creation and optimizer layout setup on the iSolarCloud App, see
"7.7 Plant Creation and Device Management"
In the multi-inverter scenario where optimizers are installed, start the inverters
one by one in the proper order. Do not start the inverters all at the same time.
In case the PV system, where the inverter is installed, is equipped with optimiz-
ers and the physical layout of optimizers has been successfully set, before re-
moving the optimizers from the system or relocating the inverter to a PV
system with no optimizers, please clear the physical layout of optimizers via
iSolarCloud.
70
"7.2 Installing App"
for details.
"7.4.2 Initialization Procedure"