10 Appendix
Parameters
Overvoltage Category
Active Anti-Islanding Method
General Data
Dimensions (W*H*D)
Weight
Topology
Degree of protection
Corrosion
Night power consumption
Operating ambient temperature
range
Allowable relative humidity
range (non-condensing)
Cooling method
Max. operating altitude
Display
Communication
DC connection type
AC connection type
AC Cable specification
Grid Support
Country of manufacture
Note(3):For Australia.
Note(4):
•
The voltage difference between MPPTs should be less than 80 V.
•
The voltage of the configured string should be higher than the lower limit of the rated
MPPT voltage.
Parameters
Input (DC)
Recom-
mended
max. PV in-
put power
132
OT terminal (16~35 mm²)
Q at night function, LVRT, HVRT,active & reactive
SG25CX-
SG30CX-
P2
(5)
P2
(5)
35 kWp
42 kWp
SG30CX-P2
(3)
DC II / AC III
Frequency Shift
600*625*240 mm
35 kg
Transformerless
IP66
C5
≤5 W
-30 to 60 ℃ (> 45 ℃ derating)
0 – 100 %
Smart forced air cooling
4000 m
LED, Bluetooth+APP
RS485 / WLAN / Ethernet, Optional: 4G
Evo2 (Max. 6 mm² )
Outside diameter 18~38mm
power control and power ramp rate control
China
SG33CX-
SG36CX-
P2
(5)
P2
(5)
46.2 kWp
50.4 kWp
User Manual
SG50CX-P2
(3)
36 kg
OT or DT terminal (35~50
mm²)
SG40CX-
SG50CX-
P2
(5)
P2
(5)
56 kWp
70 kWp