Error Messages For Gas Units - Rational iCombi Pro Original Instructions For Use

Table of Contents

Advertisement

Error
message
Service 43.1
Service 46.1
20.5.2

Error messages for gas units

If your unit it connected to the gas supply, the following additional error message
could appear. For all error messages, please contact your RATIONAL Service
Partner [} 170]. Always have the serial number of your unit ready.
Error report
Service 32.1
Service 32.2
Service 32.3
Service 33.1
Service 33.2
Service 33.3
Service 34.32
Service 60
Original instructions for use
Cause
The internal water supply is not
closing.
The water supply is malfunctioning.
Cause
The gas burner is faulty.
Close the shut-off valve on
the gas line.
The gas burner is faulty.
Close the shut-off valve on
the gas line.
The gas burner is faulty.
Close the shut-off valve on
the gas line.
The gas burner is faulty.
Close the shut-off valve on
the gas line.
The gas burner is faulty.
Close the shut-off valve on
the gas line.
The gas burner is faulty.
Close the shut-off valve on
the gas line.
The internal data
communication is faulty.
The initialisation of the
ignition box is defective.
Switch the unit off and on
again. If the error is still
displayed, call your Service
Partner.
20 | Inspiration and help
Cooking possible
Only hot air mode is
available.
Yes
Cooking possible
No
No
No
No
No
No
Yes