17
Automatic cleaning - iCareSystem
The iCareSystem is the intelligent cleaning and descaling system in the iCombi
Pro. It recognises how dirty the unit is and proposes the ideal cleaning program
and the optimal quantity of care products.
Eco mode
Cleaning programs
Cleaning status
17.1
General safety information
Only use the manufacturer's recommended Active Green cleaner tabs and
n
care tabs in automatic cleaning.
To avoid scalding and burn injuries:
Allow the cooking system and all functional components to cool down before
n
starting automatic cleaning.
To avoid severe chemical burns:
Cleaning and care products can cause severe eye damage and chemical burns
n
to the skin. Always wear securely fitting safety eyewear and chemical-
resistant gloves when cleaning the unit.
Keep the cooking cabinet door closed during automatic cleaning. Otherwise,
n
hot steam and corrosive cleaning chemicals could escape. If you open the
cooking cabinet door during automatic cleaning, a message will appear
prompting you to close it again.
Make sure the core temperature probe is not hanging out of the cooking
n
system while automatic cleaning is in progress. This could damage the seal on
the cooking cabinet door and allow corrosive cleaning chemicals to escape.
Do not clean the externally attached core temperature probes using
n
automatic cleaning.
Before preheating the cooking system for use, remove all cleaning products
n
and cleaning product residues.
How to respond if you come into contact with cleaning chemicals:
Original instructions for use
17 | Automatic cleaning - iCareSystem
Normal mode
Care status
147 / 188
Need help?
Do you have a question about the iCombi Pro and is the answer not in the manual?