ERR
Description
001
EEPROM error
111
Floor pan leakage
Signal of the two door contact
118
switches unequal
Boiler level not reached during
201
first filling (with integrated pres-
sure booster pump)
Boiler level not reached on time
202
during filling (with integrated
pressure booster pump)
No change detected by the
boiler level switch when empty-
203
ing (with integrated pressure
booster pump)
No change yet detected at the
boiler level switch (with inte-
204
grated pressure booster pump
installed) after the rinse time ex-
pired
Boiler temperature not reached
205
after max. heat time (P310)
206
Wash time increase
Boiler temperature sensor short-
210
circuit
Boiler temperature sensor inter-
211
ruption
"Actual" boiler temperature too
212
high (>95°C)
9760413
Possible cause
EEPROM
– Not present/defective
– Installed incorrectly
– Incorrect data/empty
There is a leak
Malfunction/defect door contact
switch
Fresh water inlet insufficient (wa-
ter tap closed)
Feed hose kinked/discon-
nected/leaks
Inlet filter soiled
Solenoid valve defective
Boiler switch defective
Pressure booster pump defective
Plug connections disconnected
(e.g. pressure booster pump)
Start capacitor defective
Boiler level switch defective
No signal to or from pressure
booster pump and I/O circuit
board
No signal boiler full - from I/O cir-
cuit board
Boiler heating defective/melting
beads, heating element
Temperature sensor defective, in-
correct installation position
Boiler protection defective, output
switch triggered
No signal from I/O circuit board
Boiler not ready for final rinse on
time (temperature or level not
reached)
Boiler heating defective (melting
beads)
Temperature sensor defective
Boiler protection defective, output
switch triggered
No signal from I/O circuit board
Sensor defective
Sensor position not correct
Plug contact not connected
properly
Contactor sticking
Incorrect sensor/defective sensor
Measures / remedial action
Not possible to continue
working
Call a service technician!
Not possible to continue
working
Call a service technician!
Not possible to continue
working
Call a service technician!
Check water supply
Check feed hose
Check pre-filter/sieve and
clean, if necessary
Where appropriate, call a
service technician!
Not possible to continue
working
Call a service technician!
Not possible to continue
working
Call a service technician!
Acknowledge message, con-
tinued work possible
Let programme run without
intervention by the operator
If it occurs frequently, call a
service technician!
Not possible to continue
working
Call a service technician!
Not possible to continue
working
Call a service technician!