Meiko UPster H 500 M2 Original Operating Instructions page 19

Hood type dishwashing machine
Hide thumbs Also See for UPster H 500 M2:
Table of Contents

Advertisement

5
Technical data
9760413
The standard setting for a dishwasher with A
The tank temperature during washing is up to 74° C.
For tank temperatures of 65° C or higher, each tank temperature is assigned a
factor.
Using the measured tank temperature, a value is determined and added every
second until the hygiene value A
The rinsing process runs until the end of the programme cycle time, but at least
until the temperature value is reached. After this comes a pause for draining
and the final rinse.
The display shows the current A
Thermolabel control
In a way which is similar to A
disinfection process which uses moist heat. The dishwasher heats the rinse water to
a higher temperature in order to eliminate germs. The efficacy of the disinfection can
be tested using a measurement strip, the Thermolabel. The measurement strip
changes colour after 4 seconds at 71 °C for a wash item.
During washing, the tank temperature is heated up to 71° C and maintained at
that temperature.
The rinsing process runs until the end of the programme cycle time, but at least
until the temperature value is reached. After this comes a pause for draining
and the final rinse.
Washing at high temperatures and long spells in the wash tank can lead to
glass corrosion and premature wear to decoration.
Thermal disinfection - control
Thermal disinfection works according to the same principle as Thermolabel control,
but other requirements apply:
The disinfection temperature is ≥ 80° C, which must be maintained on the
washware for ≥ 30 s.
During washing, the tank temperature is heated up to 76° C, and the final rinse
temperature is 88 °C.
The rinsing process runs until the end of the programme cycle time, but at least
until the temperature value and specified stop time are reached. After this
comes a pause for draining, final rinse and a subsequent application time.
Thermolabel and thermal disinfection control offer a disinfection effect that exceeds
the standard, such as for hospitals, care homes, requirements according to the
ÖGSV Guideline.
MEIKO has created a dimensional drawing that shows machine dimensions as well
as connection and consumption values.
Further data should be taken from the MEIKO dimensional drawing.
Net weights
Versions
UPster H 500 M2
+ ActiveClean water softener
+ AirConcept heat recovery
+ GiO MODULE reverse osmosis
– control is the hygiene value A
0
30 is reached.
0
value.
0
control, machines with Thermolabel control have a
0
30:
0
Weight ap-
prox.
110 kg
9 kg
20 kg
23 kg
19 / 56

Advertisement

Table of Contents
loading

This manual is also suitable for:

M004dwht10m2-20

Table of Contents