8.10.2 Ventilating the pipes
8.10.3 Start regeneration manually
8.10.4 Replace counter for partial desalination cartridge (optional)
9760413
The ventilation of the detergent or rinse pipes must be performed if air is sucked in
from the dosing units. This occurs if a canister is completely emptied during opera-
tion, or if one of the suction lances is not threaded through to the base of the canis-
ter.
1. Switch to authorisation level 1 Service level (10001), see page 41.
2. Select the entry 1–3 for ventilating the detergent pipe, and entry 1–2 for the
rinse pipe.
3. Confirm the selection.
The respective pipes are being ventilated, and the remaining time in seconds is
displayed. If necessary, repeat ventilation.
Venting can be cancelled with the on/off key.
1. Switch to authorisation level 1 Service level (10001), see page 41.
2. Select the entry 1–4.
3. Confirm the selection.
Regeneration begins.
The service level can be exited with the On/Off key.
For dishwashers with a partial desalination cartridge and activated end-of-service
indicator, the counter must be reset after changing the partial desalination car-
tridge.
1. Switch to authorisation level 1 Service level (10001), see chapter "Change au-
thorisation level" on page 41.
2. To reset the counter, select entry 1-5.
3. Confirm the selection to reset the value.
The setting level can be departed with the on/off key.