6.1.5
Requirements to the electrical connection
Fuse protection
Main switch/mains connection cable
Electrical safety
22 / 56
Note
The wiring diagram is located in the switch cabinet of the dishwasher. This must re-
main in the dishwasher!
The rating plates with the electrical connection values are located on the switch
cabinet behind the front panel, outside on the lower left or lower right, and on the
separate GiO MODULE (if it is part of the machine).
Electrical connection must be carried out in accordance with the locally applicable
regulations (e.g. HD 60364-1/IEC 60364-1/VDE 0100-100) so the machine can be
connected to the mains supply in accordance with the installer's regulations. How-
ever, national installer's regulations may differ. The machine and accessory appli-
ances are intended for permanent connection to the on-site power supply and the
on-site protective equipotential bonding and have been tested accordingly before
being brought to market.
Set up the machine according to the local conditions and according to the rated
current (see rating plate) as a separately fused circuit (final circuit). Take note
of the available connection variants.
The requirements for limiting voltage changes, fluctuations and flicker in ac-
cordance with IEC 61000-3-11 for this dishwashing machine are fulfilled if the
network has a current-carrying capacity of ≥ 100 A.
Install a main switch with all-pole disconnection from the mains in accordance
with the regulations for installers in the permanently installed on-site installa-
tion.
The main switch must be easily accessible for the operating personnel.
The contact opening width must correspond to overvoltage category III in each
pole.
Mains power cables, unless part of the standard product scope of supply, must
be oil-resistant, sheathed, flexible cables no lighter than a normal polychloro-
prene-sheathed cable (or other equivalent synthetic elastomer) with the mark-
ing 60245 IEC 57.
Refer to the circuit diagram for technical data for the main switch such as
torque and stripping length.
The electrical safety of this machine is only ensured if it is connected to a
properly installed protective conductor system. It is very important to verify this
fundamental safety feature. If in doubt, have the building wiring checked by an
electrician.
Carry out the protective measures as well as the connection of the equipotential
bonding in accordance with the regulations of the local power supply compa-
nies as well as the locally applicable regulations.
As an alternative to equipotential bonding, the operator can, acting on its own
responsibility, use a mains-side residual current device (RCM or RCD) for per-
sonal protection. A type "A" according to IEC 60755 is sufficient.