4.8
AirConcept exhaust heat recovery (optional equipment)
4.8.1
Disinfection control
18 / 56
Capacity of the water softener between two regenerations
Hardness (° dH)
8
10
12
14
16
18
20
22
24
26
28
30*
32
34
36
38
40
42
* Factory setting
The AirConcept exhaust heat recovery system is installed behind the hood:
Loss of steam into the surrounding area is reduced.
Saves energy by targeted suction of hot vapour.
Fresh water is heated in the heat exchanger.
Not available for dishwashers that are supplied with hot water.
Caution
Glass corrosion and loss of decorations due to high water temperatures and
long wash cycle times
Make sure that the dishes and glassware used are suitable for the high stress
placed on them.
MEIKO offers two types of machine with thermal disinfection for institutions with ad-
ditional hygiene requirements. Both versions have greater heating performance in
the wash tank than standard machines.
A
control
0
The term A
refers to a way of measuring how microorganisms are eliminated by
0
moist heat disinfection methods. By using a moist heat disinfection method, it is ex-
pected that a specific temperature over a period of time has the effect of eliminating
a predictable number of microorganisms with a particular resistance.
Capacity (l)
250
200
167
143
125
111
100
91
83
77
71
67*
63
59
56
53
50
48