Meiko UPster H 500 M2 Original Operating Instructions page 47

Hood type dishwashing machine
Hide thumbs Also See for UPster H 500 M2:
Table of Contents

Advertisement

Maintenance work
Visual inspection
5. Hood and hood counterbalance
Check hood for ease of movement
Check hood handle bearings visually and for correct operation
Clean hood guide and back wall seal
Check life span of springs
Replacement
6. Fresh water installation
Check valves, clean dirt trap
Check boiler level switch is working and not leaking
Check boiler, hoses, clamps and plastic parts do not leak
Check boiler drainage system does not leak
7. Wastewater installation
Replace flap on ventilation valve
Check operation of drain pump during drainage
Check that pumps, hoses are not leaking
8. Detergent dosing
Replace peristaltic hose
Check detergent dosing system is working and not leaking
9. Rinse aid dosing
Replace peristaltic hose
Check rinse aid dosing system is working and not leaking
10. Test run with function test of whole machine
Check filling and heating until it is ready for operation
Visual inspection of the entire machine for leaks
Carry out test wash and check results
11. Options
ActiveClean water softener (if applicable)
Check water hardness setting
Check the seal on the lid of the salt container
Start and check the regeneration process manually
Integrated reverse osmosis system (if applicable)
Visually check whole system for leaks
Prefilter change standard membrane (< 0.1 mg/l)
Change pre-filter, chlorine-resistant membrane (≥ 0.1 and ≤ 2.0 mg/l)
Check fine sieve insert and choke in concentrate pipeline
Check correct function of concentrate drain and check for deposits
Fill in separate log: Certificate of Commissioning, GiO
Partial demineralisation (PD)/full demineralisation (FD) (if applicable)
Check operation
Exhaust air heat recovery (if applicable)
Check operation of fan
Check operation of solenoid valve
Carry out visual inspection and check for leaks
9760413
Maintenance
requirement
H
H
H
H
loads or 12 years
U/H
U/H
U/H
U/H
U/H
U/H
U/H
U/H
U/H
U/H
U/H
U/H
U/H
U/H
U/H
U/H
U/H
U/H
U/H
U/H
U/H
U/H
U/H
U/H
H
H
H
annually
annually
annually
annually
after 650,000
annually
annually
annually
annually
annually
annually
annually
annually
annually
annually
annually
annually
annually
annually
annually
annually
annually
annually
every six
months
every three
months
annually
annually
annually
annually
annually
annually
annually
47 / 56

Advertisement

Table of Contents
loading

This manual is also suitable for:

M004dwht10m2-20

Table of Contents