8.5
Fill consumables
8.5.1
Replace canister
34 / 56
Warning
Risk of injury from contact with chemicals
•
Observe the safety data sheets and dosing recommendations of the chemical
manufacturers.
•
Use eye protection.
•
Wear protective gloves.
•
Do not mix different chemical products.
Note
Information on cleaning chemicals, see chapter "Detergent and rinse aid" on page
16.
Note
The canisters for detergent and rinse aid are located in close proximity to the dish-
washing machine.
Note
When using a suction lance which detects whether a canister is empty, a shortage
of detergent or rinse aid will be indicated on the display.
A canister is empty.
1. Remove the suction lance from the empty canister and insert it into a full canis-
ter.
2. If necessary, ventilate the pipelines, see page 43.
9760413