15.3.10 Writing commands
Writes a sequence program to the FX PLC. (Overwrite/Insert)
1
Writing basic commands
(1) Operations
(a) Inputting command only (Ex.: ANB, ORB command etc.)
Stop the FX PLC
(b) Inputting command and device (LD, AND commands etc.)
Stop the FX PLC
(c) Inputting command, No. 1 device, No. 2 device (MC, OUT (T, C) commands, etc.)
Stop the FX PLC
(2) Example
(a) Writing ORB command
Stop the FX PLC
15 - 27
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.10 Writing commands
MODE
For overwriting: (WRITE mode)
For insertion: (INSERT mode)
MODE
For overwriting: (WRITE mode)
For insertion: (INSERT mode)
Input the device name and device number
MODE
For overwriting: (WRITE mode)
For insertion: (INSERT mode)
Input the device name and device number
SP
Moving the cursor to the position to write the command
When starting to write a command, place the cursor on the command line (the line
on which the step number is displayed).
You cannot write a command with the cursor on an operand or set value line.
2 LDI
3 MOV
< READ >
MODE
< WRITE >
With
or
, move the
cursor to the position to
overwrite/insert the command.
Input the command
Input the command
GO
Input the command
M
100
Command line (Place the cursor on this line.)
12
D
0
Operand, set value line (Cannot operate on this line.)
D
10
4 LDI
5 AND
6 NOP
7 NOP
Set the
WRITE or
4 LDI
INSERT
5 AND
mode
6 ORB
7 NOP
GO
Input the device name and device number
GO
X
004
X
005
ORB
GO
X
004
X
005

Advertisement