P0132; Troubleshooting - Yamaha XSR 900 2022 Service Manual

Hide thumbs Also See for XSR 900 2022:
Table of Contents

Advertisement

EAS20571

P0132

EAS33051

TROUBLESHOOTING

Item
O
sensor: short to power circuit is detected. Normal signal is not received from the O
2
Fail-safe system
• Able to start engine
• Able to drive vehicle
Procedure
1. Installed condition of O
• Check for looseness or pinching.
Refer to "ENGINE REMOVAL" on page 5-9.
Is check result OK?
YES
→ Go to step 2.
NO
a. Reinstall or replace the sensor.
b. Turn the main switch to "ON", and then check the DTC using the malfunction mode of the YDT.
Is it in the "Recovered" condition?
YES
→ Go to step 7, and complete the service.
NO
→ Go to step 2.
2. Connection of O
sensor coupler.
2
• Check the locking condition of the coupler.
• Disconnect the coupler and check the pins (bent or broken terminals and locking condition of the
pins).
Is the coupler condition normal?
YES
→ Go to step 3.
NO
a. Connect the coupler securely or replace the wire harness.
b. Turn the main switch to "ON", and then check the DTC using the malfunction mode of the YDT.
Is it in the "Recovered" condition?
YES
→ Go to step 7, and complete the service.
NO
→ Go to step 3.
3. Connection of ECU coupler.
• Check the locking condition of the coupler.
• Disconnect the coupler and check the pins (bent or broken terminals and locking condition of the
pins).
sensor.
2
9-132
P0132
sensor.
2

Advertisement