Digi IX20 User Manual page 1066

Hide thumbs Also See for IX20:
Table of Contents

Advertisement

Monitoring
9. Add collectors:
a. Add a collector:
(config)> add monitoring netflow collector end
(config monitoring netflow collector 0)>
b. Set the IP address of the collector:
(config monitoring netflow collector 0)> address ip_address
(config monitoring netflow collector 0)>
c. (Optional) Set the port used by the collector:
(config monitoring netflow collector 0)> port port
(config monitoring netflow collector 0)>
d. (Optional) Set a label for the collector:
(config monitoring netflow collector 0)> label "This is a collector."
(config monitoring netflow collector 0)>
Repeat to add additional collectors.
10. Save the configuration and apply the change
(config monitoring netflow collector 0)> save
Configuration saved.
>
11. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.
IX20 User Guide
Configure NetFlow Probe
1066

Advertisement