Clearing Faults in a Sync Pulse System
The following table describes some of the errors you might encounter with a Pinnacle
Plus+ master/slave system.
Table 5-4. Errors Associated With The Pinnacle Plus+ Sync Pulse System
Transmit unit reports:
"Multiple Sync Pulse
Transmitters Detected"
Receive unit reports:
"No Sync Pulse
Transmitter Detected"
Any unit reports:
"System Input Power
Fault"
Note: For more information about error codes, please refer to the "Troubleshooting"
5702269-C
Page 169 of 204
Condition
• Two or more units have been designated as
• The sync pulse cable has been removed.
• All units in the system are designated as receivers.
• One of the units in the system is not energized (that
chapter.
Installation
Possible Cause(s)
transmitters.
Note: Multiple transmitter errors are detected
only at power up or when changing port
directions.
Note: No transmitter errors are detected any time
the unit is powered up.
is, does not have input power).
Pinnacle™ Plus+ 10 kW
5-23
Ex. 1024 Page 169