Maintenance and Troubleshooting
30.1.2. Error and warning messages while the X.TUNE function is
running
Display
TUNE
err/break
X.TUNE locked
X.TUNE
ERROR 1
X.TUNE
ERROR 2
X.TUNE
ERROR 3
X.TUNE
ERROR 4
X.TUNE
ERROR 5
X.TUNE
ERROR 6
X.TUNE
ERROR 7
Table 100:
Error and warning message on X.TUNE
Causes.of.error
Manual termination of self-parameterization
by pressing the
key
EXIT
The X.TUNE function is blocked
No compressed air connected
Compressed air failed during Autotune
(X.TUNE).
Actuator or control system deaeration side
leaking
Control system aeration side leaking
The rotation range of the position sensor is
exceeded by 180°
The end positions for POS-MIN and
POS-MAX are too close together
Incorrect assignment POS-MIN and
POS-MAX
Remedial.action
Input access code
Connect compressed air
Check compressed air supply
Not possible, device defective
Not possible, device defective
Correct attachment of the position sensor
shaft on the actuator (see chapter "12.2").
Check compressed air supply
To determine POS-MIN and POS-MAX,
move the actuator in the direction indi-
cated on the display.