Auxiliary functions
24.2.18. EXTRAS – Setting the display
This function can be used to individually set the display.
• In DISP.ITEMS the display of the process level can be individually set.
To do this, further menu options can be activated for the display of the process level. POS and CMD are acti-
vated in the as-delivered state.
• In START-UP.ITEM one of the activated menu options is specified as a start display after a restart.
• The type of display is selected via DISP.MODE.
normal = black font on light background.
inverse = white font on dark background.
EXTRAS
ENTER
EXIT
Figure 70:
Operating structure EXTRAS
DISP.ITEMS
ENTER
EXIT
START-UP.ITEM
ENTER
EXIT
DISP.MODE
ENTER
EXIT
DISP.LIGHT
ENTER
EXIT
SELEC
POS
Activate menu options
to be indicated on the
CMD
display
CLOCK
X.TUNE
SELEC
POS
Select start display
CMD
X.TUNE
SELEC
Black font on light
normal
background
White font on dark
invers
background
SELEC
• Background lighting
on
on
• Background lighting
off
off
Background lighting
user active
switches off after 10 sec
english