Chapter 5

Connecting the Pressure Override Switch

On the console cable harness (P/N 115-0171-775), identify the connector labeled 'OVERRIDE'.
1.
Connect the 'OVERRIDE' connector to the pressure override switch.
2.
Tighten the bolt on the connector to secure the connection and to help prevent moisture penetration.
3.

Route the Console Cable Harness

Once the SmarTrax hydraulic valve and pressure override switch are connected to the console cable harness,
the remaining connectors must be routed into the cab.
Locate an access point through which the console cable harness (P/N 115-0171-775) may be routed into
1.
the cab.
Route the cable to the access point and use the provided cable ties to secure the cable to avoid catching or
2.
damaging the cable during normal equipment operation.
Note:
When routing the SmarTrax console cable harness, follow the path of other hoses or cables to
avoid potential wear areas.
Feed enough of the cable into the cab to allow each cab control component to be connected.
3.
Spool and secure any excess cable.
4.

Install the Foot Switch

Select a location for the SmarTrax foot switch (P/N 063-0172-470) within easy reach of the operator to fully
1.
press the front of the pedal.
Use the SmarTrax foot switch as a template and pre-drill holes in the floor.
2.
Secure the foot switch to the floor with four screws or bolts through each of the mounting holes.
3.
Locate the connector labeled 'ENABLE' on the SmarTrax console cable harness (P/N 115-0171-775) and
4.
connect it to the foot switch cable.
Foot Switch Mounting Example
FIGURE 2.
18
CaseIH MX 210, 230, 255, and 285 SmarTrax Installation Manual