Connect The Pressure Override Switch; Route The Console Cable Harness - Raven SmarTrax Installation Manual

Gvm prowler (‘08 & newer, & all 120’ booms)
Hide thumbs Also See for SmarTrax:
Table of Contents

Advertisement

Chapter 5
Solenoid Connections on the SmarTrax Valve
FIGURE 1.
SmarTrax Hydraulic
valve mounting
location

Connect the Pressure Override Switch

On the console cable harness (P/N 115-0171-775), identify the connector labeled 'OVERRIDE.'
1.
Connect that 'OVERRIDE' connector to the pressure override switch.
2.
Tighten the screw on the connector to secure the solenoid connection.
3.

Route the Console Cable Harness

Once the SmarTrax hydraulic valve and pressure override switch are connected to the console cable harness,
the remaining connectors must be routed into the cab.
Locate an access point through which the console cable harness (P/N 115-0171-775) may be routed into
1.
the cab.
Route the cable to the access point and use the provided cable ties to secure the cable to avoid catching or
2.
damaging the cable during normal equipment operation.
Note:
When routing the SmarTrax console cable harness, follow the path of other hoses or cables to
avoid potential wear areas.
Feed enough of the cable into the cab to allow each cab control component to be connected.
3.
Spool and secure any excess cable.
4.
20
GVM Prowler ('08 & Newer & All 120' Booms) SmarTrax Installation Manual

Advertisement